Normal Operating
Procedures
DA 42 AFM
Page 4A - 38 Rev. 8 15-Dec-2017 Doc. No. 7.01.05-E
1. Transfer the first half of the auxiliary fuel:
As soon as the fuel quantity in each main fuel tank is 17 US gal or less, set both FUEL
TRANSFER switches to ON until the main tanks are full again.
Monitor the fuel quantity indicator to verify that fuel is properly transferred to both main
fuel tanks (approx. 1 US gal per minute). If the fuel quantity in a main tank does not
increase during fuel transfer, proceed according to Section 4B.11 - L/R FUEL
TRANSFER FAIL.
2. Transfer the second half of the auxiliary fuel:
Repeat the procedure described above.
NOTE
Transfer the fuel from the auxiliary tanks to the main tanks
as soon as possible. The fuel in the auxiliary tanks must be
transferred to the main tanks to become available for the
current flight mission.
END OF CHECKLIST
4A.6.10 DESCENT
1. POWER lever ........................ as required
2. Airspeed ............................ as required
3. Trim................................ as required
4. Annunciations/Engine/System Page ....... monitor
END OF CHECKLIST