DG-GS1528HP/C User Manual
50
Figure62 RMON history group configuration page
(3) RMON alarm group configuration page
Figure 62 shows the RMON alarm group configuration page. You can use this page to create or modify an RMON
alarm group. Select a configured alarm group from the drop-down list to view/configure its information. Select New to
create it. The index number range is from 1 to 60, and the interval range is from 1 to 3600. In seconds, the monitoring
object must fill in the MIB node. The comparison method can choose absolute (absolute value) or delta (change
amount). In addition, the upper and lower limit valves must be filled in. Value, event index, owner is optional. The
alarm value is read-only and shows the sampled value when the alarm was last issued. The event index refers to the
index number of the RMON event group and must be configured in advance.
Figure 62 RMON alarm group configuration page