EasyManua.ls Logo

Digistar TMR3610 - Page 45

Digistar TMR3610
65 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D4023-EN TMR3610 Operators Manual 45
SETTING
[display]
D.A.N.
NO.
OPTIONS [displayed]
BOLD=DEFAULT
DESCRIPTION
AUTO PRINT
(APRINT)
2303
ON/OFF
If ON -pressing keys auto-
prints weight values.
PRINT FORMAT
(PRTFMT)
2304
AUTO, WTONLY, DOWNLD,
DT+TM, ID+TM, IDWTTM,
BATCH1, PRTAC1, PRTAC2,
PRTAC3, PRWTRC,
WTRCTM,3200-A, 3200-B,
SCLABC,32-TMR, FDINFO,
FEED-1
Select alternate & comma
(CSV) formats.
PRINT
ACCUMULATION
(PRTACC)
2305
0
Shows a running total of
weights printed.
REMOTE DISPLAY
(RMDISP)
2401
EZ2, EZ3MUX, COG, NONE
Select type of remote display
REMOTE TERMINAL
RMTERM
2402
ON/OFF
Sends display data to serial
remote terminal interface
BAR GRAPH MODE
BARGRP
2411
OFF, RIGHT, LEFT, MIDOUT, MID
IN
Selects output for a bar graph
display when used with an
RD4000 Remote Display
WEIGHT GRAPH
WTGRPH
2412
ON/OFF
Enables graph to be used
with weight when used with a
RD4000 Remote Display.
BAR WEIGHT
(BAR WT)
2413
12000
Enter the full scale gross
weight for the bar graph
display.
PRESET GRAPH
(PRGRPH)
2414
ON/OFF
Enables graph to be used
with presets when used with
an RD4000 Remote Display.
TIMER GRAPH
(TMGRPH)
2415
ON/OFF
Enables graph to be used
with timers when used with
an RD4000 Remote Display.
MENU 3 - MOTION & WEIGHT
DISPLAY COUNT
(COUNT)
3001
.01,.02,.05,.1,.2,.5,1,2,5,10,20,
50,100
Select display count size of
weigh values.
CAPACITY
(CAP)
3002
40,000
Enter MAXIMUM weight
measurable on scale.
WM1 ADJUST 1
(WMA1-1)
3003
10
Increase this number to
smooth weighing
WM1 ADJUST 2
(WMA1-2)
3004
4
0=off. Use value less than
WMA1-1 for quick response
weight.
Direct Access Numbers (D.A.N.)

Table of Contents

Related product manuals