EasyManua.ls Logo

Digistar TMR3610 - Page 46

Digistar TMR3610
65 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
46 TMR3610 Operators Manual D4023-EN
SETTING
[display]
D.A.N.
NO.
OPTIONS [displayed]
BOLD=DEFAULT
DESCRIPTION
WM1 ADJUST 3
(WMA1-3)
3005
4000
Enter the weight to active
quick response weight
Default-10% of scale
capacity
WM2 ADJUST 1
(WMA2-1)
3006
30, value must be less than 100
and more than 2.
Increase this number to
smooth weighing
WM2 ADJUST 2
(WMA2-2)
3007
10, value must be less than 100
and more than 0.
10=off. Use value less than
WMA2-1 for quick response
weight.
WM2 ADJUST 3
(WMA2-3)
3008
4000
Enter the weight to active
quick response weight
Default-10% of scale capacity
MOTION
(MOTION)
3101
ON/OFF
ON = Motion arrow flashes
with unstable weight.
Prevents: Print, Zero, Tare,
Advance
MOTION WEIGHT
(MOT WT)
3102
0
Enter weight used to detect
motion. 0=Standard
detection
MENU 4 - PRESET, ALARM, and TIMER
PRE ALARM
METHOD
(P MTHD)
4001
WEIGHT, PERCENT
Select weight or percentage
method for pre-alarm
PRE-ALARM
(P-ALM)
4002
100
Enter a value to activate an
early warning that indicator is
reaching the preset.
ALARM OUTPUT
(AL OUT)
4003
OFF, PRESET, TR
Select preset or TR to control
relay, horn & lamp.
BUZZER
(BUZZER)
4004
OFF, ON, 1-10
ALARM BUZZER -allows user
to turn off alarm horn when
loading/unloading
RELAY
(RELAY)
4005
OFF, PRESET, SETPNT
Selects the behavior of the
+12VDC alarm output
PRESET DELAY
(PRTDLY)
4006
10
Set time to automatically
advance/print entered preset
GROSS SET PNT
OUTPUT SETOUT
4101
OVER/UNDER
Select when the +12VDC
Alarm Output becomes
active.
GROSS SET POINT
CHNG SETCHG
4102
500
Set required weight change to
turn off +12VDC Alarm
Output.
Direct Access Numbers (D.A.N.)