D4023-EN TMR3610 Operators Manual 47
SETTING
[display]
D.A.N.
NO.
OPTIONS [displayed]
BOLD=DEFAULT
DESCRIPTION
GROSS SET POINT
DELAY SETDEL
4103
0
Set time delay before the
+12VDC Alarm Output can
Turn On/Off.
GROSS SET POINT
(SETPNT)
4104
5000
Set a gross weight in long
form that will activate
+12VDC Alarm Output on
Power cord.
SET POINT COUNT
(SETCTR)
4105
0
Counts how many times set
point is activated.
SET POINT WEIGHT
SOURCE
(STWTSC)
4106
SERIAL/NORMAL
Sets weight source for use
with set point feature.
TOLERANCE
METHOD
(T MTHD)
4201
WEIGHT, PERCENT
Select weight or percentage
method for preset tolerance
TOLERANCE
(TOLER)
4202
0
Select tolerance weight
percentage to accept preset.
TOLERANCE
OVERLOCK
(OVERLK)
4203
OFF/ON
Prevents auto-advancing if
preset exceeds tolerance
TIMER,
COUNTER
(TMRCTR)
4301
TIMER, COUNTER
Select time or mixer
revolutions to decrement mix
timer/counter.
DRIVE RATIO
(DRATIO)
4302
1.00
Enter the number of input
pulses that equal 1 mixer
revolution. REVCTR needs to
be enabled in the setup
options. D.A.N. 4301 set to
COUNTER.
MENU 5 - COM PORT SETUP
REMOTE DISPLAY
PORT
(RMDPRT)
5001
OFF, COM1, COM2, COM3
Sets serial remote display
output
RADIO PORT
(RADPRT)
5002
OFF, COM1, COM2, COM3
Sets internal radio port
EXTERNAL RADIO
PORT (exrprt)
5003
OFF, COM1, COM2, COM3
Sets external radio port
Direct Access Numbers (D.A.N.)