The information contained here are property of DIGITAX Automotive Electronics Italy, and extremely confi dential. Any disclosure, copying, distribution to third
party
is strictly prohibited.
50
342 Available for any possible so ware extension
343 Must the black trips saving opera on be avoided? No / Yes
344 Must the cash trips saving opera on be avoided? No / Yes
345 Must the Credit trips saving opera on be avoided? No / Yes
346 Must the Power off saving opera on be avoided? No / Yes
347 Must the shi s saving opera on be avoided? No / Yes
from Q 348 / Available for custom parameters / to Q 367
368
Check Printer Status before start the trip - If Yes the taximeter checks the printer status before star n a new trip and if the printer is not
connected or is not ready then the trip will not start
No / Yes
369 Disable Print out shi report - If Yes the report will not be printed, if No the report will be printed at the end of the shi No / Yes
370 Request GPS Coordinates - If Yes the taximeter will request to the dispatcher the coordinates at the start and at the end of the trip No / Yes
CONNECTION TO THE DISPATCHER
371
Transmit undefi ned status to dispatcher? - Transmit an undefi ned status to the dispatcher?
The allowed answer is either: 0 (No: don’t transmit) or: 1 (Yes: transmit).
No / Yes
372
Transmit ForHire status to dispatcher? - Transmit the ForHire status to the dispatcher?
The allowed answer is either: 0 (No: don’t transmit) or: 1 (Yes: transmit).
No / Yes
373
Transmit Stopped status to dispatcher? - Transmit the Stopped status to the dispatcher?
The allowed answer is either: 0 (No: don’t transmit) or: 1 (Yes: transmit).
No / Yes
374
Transmit Hired status to dispatcher? - Transmit the Hired status to the dispatcher?
The allowed answer is either: 0 (No: don’t transmit) or: 1 (Yes: transmit).
No / Yes
375
Block taximeter if driver ID is 0? - Should the taximeter be blocked if the iden fi ca on number of the driver is 0?
The allowed answer is either: 0 (No: don’t block) or: 1 (Yes: block).
No / Yes
376
Assign ID 9999999 if driver ID is 0? - Should driver ID 9999999 be assigned if the iden fi ca on number of the driver is 0?
The allowed answer is either: 0 (No: don’t assign) or: 1 (Yes: assign).
No / Yes
377 If driver = 0, must the meter show “Close” in For Hire mode? No / Yes
378 Reques ng Ticket the taximeter powers on the Printer? - If Yes, a er prin ng, the taximeter powers off the printer No / Yes
379 Defi ne if thermal printer width is 44 mm or 57 mm No / Yes
380 Must blank lines prin ng be avoided? No / Yes
381 Is thermal printer in usage? No / Yes
382 Where the thermal printer is connected? (0 = Com 1 1 = Com 2) No / Yes
383
Enable taximeter-dispatcher connec on? - Should the possibility to connect the taximeter with a dispatcher be enabled?
The allowed answer is either: 0 (No: disable) or: 1 (Yes: enable).
No / Yes
384
Dispatcher is connected to COM1 or COM2? - Is the dispatcher connected to COM1 or to COM2 ? See also Q.383 and Q.385 to Q.387.
The allowed answer is either: 0 (No: COM1) or: 1 (Yes: COM2).
0= COM1
1= COM2
385
COM1 protocol is Digitax or custom? - The protocol used for data-transmission on COM1 is the Digitax protocol or a custom protocol?
See also Q.383, Q.384 and Q.386, Q.387. The allowed answer is either: 0 (No: Digitax protocol) or: 1 (Yes: custom protocol).
0= Digitax
1= Custom
386
COM2 protocol is Digitax or custom? - The protocol used for data-transmission on COM2 is the Digitax protocol or a custom protocol?
See also Q.383 to Q.385 and Q.387. The allowed answer is either: 0 (No: Digitax protocol) or: 1 (Yes: custom protocol).
0= Digitax
1= Custom