5.3 STARTING UP THE TERMINAL
The terminal is powered by means of the switch located on the metal plate at the rear of the
equipment. When the power supply is connected, the corresponding LED POWER OK on
the front plate lights up.
Once the internal voltages become stabilized, the processing module initiates a self-check
process and a management process of the line and protection interfaces. Once the
processes are over the LEDs LINK and STATUS light up in green on the front plate.
5.4 CONFIGURATION OF THE WEB SERVER
The network configuration of the web server can be modified, if the terminal has already
been accessed, from the option Network parameters of the Server submenu of the TPU-1
Management System Equipment menu.
From the said option, it is possible to modify parameters such as IP address, subnet mask,
etc., in order for them to be compatible with the computer or computers that are going to be
connected to the terminal.
By default, the IP ADDRESS of the terminal is 172.16.6.3. When the IP ADDRESS by
default is modified, it is advisable to store the new address in some type of register as,
should the new address be forgotten, it is not possible to access the web server. The IP
address in factory is the 172.16.6.3.
If the new IP address is forgotten, by carrying out a jumper in the processing module
(MWTU) the IP address by default (172.16.6.3) as well as the default user passwords of
the system are loaded again in the terminal.
5.5 CONFIGURATION OF THE MANAGEMENT COMPUTER
This section describes the configuration of the management computer. It first indicates the
characteristics of the management computer, as well as the connection between the PC and
the terminal, in each of the possible cases so that the web application transfers or acquires
data from the TPU-1 terminals.