DFW series indicators DFW_03_12.07_EN_U
36
NOTE: In the totaliser mode in order to print the totalised weight the following must take place:
- the weight must be stable;
- the net weight must be >= of a division with normal or fast totalisation;
- the net weight must be >= of 10 divisions with automatic totalisation;
- the printing is reactivated depending on how the “rEACT” parameter has been set in the set-up environment: passage by
zero of the NET weight, weight instability, or always (see section “REENABLING THE PRINTOUTS AND THE INDICATOR
FUNCTIONS”).
Legal for Trade scale printing.
In order to be able to print with a legal for trade scale the following conditions must exist:
- the weight must be stable;
- the net weight must be >= the minimum weight (minimum of 20 divisions).
- the printing is reactivated depending on how the rEACt” parameter has been set in the set-up environment: passage
by zero of the NET weight, weight instability, or always (see section REENABLING THE PRINTOUTS AND THE
INDICATOR FUNCTIONS”).
Notes:
- The printing is confirmed by the indication on the display of the "Print" message or “-tot-” in case of totalisation.
- If the printout is not reenabled the display shows the "no.0.unS" message
- With the weight unstable the display shows the "unStAb" message.
- If the gross or net weight is less than the requested minimum weight, by pressing the ENTER/PRINT key, the display
shows the “LoW” error message.
- If the indicator is in under load or over load status, by pressin the ENTER/PRINT key, the display shows the “un.oVEr”
error message.
To configure the printouts, go to the section “PROGRAMMING THE PRINTOUTS” in the technical manual
(TECH.MAN.REF.).
9.13 REENABLING THE PRINTOUTS AND THE INDICATOR FUNCTIONS
While using the indicator, it is possible to incur into the no.0.unS error shown on the display along with an acoustic signal;
this means that the printing or the function which one wants to carry out must be reenabled (in order to avoid unwanted
executions).
It is possible to set the reenabling in different ways: “passage by zero of the net weight”, “weight instability” or “always”.
Follow the procedure below:
- Turn on the scale, press the TARE key while the firmware version is displayed (the display shows the “tyPE” menu).
- Press ZERO many times (to scroll ahead through the parameters) or TARE (to scroll backwards) until one finds the
“F.ModE” parameter.
- Press ENTER/PRINT to enter the menu.
- Scroll until one finds the “rEACt” parameter and select it.
- With the ZERO or TARE keys select the possible options: “ZEro” (passage by zero of the net weight), “inSt” (instability),
“ALWAyS”.
- Confirm with ENTER/PRINT.
- Press the C key many times until the message “SAVE?” is shown on the display.
- Press ENTER/PRINT to confirm the changes made or another key to not save.
9.14 DISPLAY OF METRIC DATA (inFO)
The indicator is fitted with a function named “INFO”, thanks to which it is possible to view the configuration metric data:
- With the 5-key indicator:
- keep the C key pressed until the display shows “inFO”, and release, or:
- press the keys MODE + C keys in sequence
-
With the 17-key indicator: depending on the model:
- press the key i once, or:
- press the keys MODE
+ C keys in sequence, or:
- keep the C key pressed until the display shows “inFO”, and release.