DFW series indicators DFW_03_12.07_EN_U
37
- The capacity value of the first range will appear.
- Press the ZERO key to scroll the following data, in this order:
Capacity 1° range Minimum weigh 1° range Division 1° range
Capacity 2° range Minimum weigh 2° range Division 2° range
Capacity 3° range Minimum weigh 3° range Division 3° range
Capacity 1° range ………
- Press the TARE key to scroll backwards the metric data.
- Press the C key to return to weighing.
NOTES:
- The minimum weigh corresponds to 20 net weight divisions.
- The data of the second and third range appear only if actually configured.
10. ADDITIONAL FUNCTIONS OF THE 17-KEY INDICATOR
10.1 STORED TARE MEMORY VALUES
It’s possible to store up to 30 tare memory values, identified by the location numbers 1 to 30, which the user can recall
when needed.
To insert or modify a tare value:
- press the keys “F”+ “9” in sequence - the display will indicate "t nn". in which nn is the storage number to be entered.
For example, by pressing “01” and then ENTER/PRINT, the display will indicate "t00000" or any value that already
exists in the tare memory location "01."
- Insert the tare value with the numeric keyboard (with the C key one quickly zeros the entered value) and press
ENTER/PRINT.
- Repeat the sequence for the following memory positions.
The value must be entered as a multiple of the scale’s minimum division.
RECALLING STORED TARE VALUES
To recall a stored value:
- Press the keys “F” + “1” in sequence. The display will indicate "t nn" in which nn is the storage number to be entered.
- Press the keys corresponding to the desired tare value location in memory (01-30) and then ENTER/PRINT, the tare
will be enabled.
10.2 ENTERING THE IDENTIFICATION CODE
It is possible to insert 2 numerical codes of up to 10 digits in length (maximum) to use as a reference during printing:
- Press the “F”+ “3” keys in sequence. The display will indicate "IId n" in which n identifies the code number which one
wants to enter.
- Press 1 or 2: the display will show 00000 or the last entered value.
- Enter the code through the numeric keyboard and confirm with ENTER/PRINT or press C to exit without saving the
modifications. During the entry, just the last 6 digits entered will be displayed; in any case it is possible to scroll all the digits
using the MODE key.
After its entry, the code will automatically be printed with its abbreviation (ID1 or ID2) in each printing that will be made. The
non significant zeros are not printed.
It is also possible to set the automatic cancellation of the code after the printing is made.
IN ANY CASE, the stored codes are cancelled when the instrument is turned off.
NOTES:
-
The values between 0'000'000'001 and 9'999'999'999 are valid; by entering 0'000'000'000 the code is cancelled.
- In the TOTALIZER functioning mode, the codes will be printed only in the printing of the total.
LOCKED / UNLOCKED CODE SELECTION
Normally the code is LOCKED, in other words once it is set it remains stored (and therefore printed) until it is cancelled or