DFW series indicators DFW_03_12.07_EN_U
60
Er
85
It is displayed when the instrument has been initialized but not yet been calibrated.
Press the TARE key when the instrument displays “Er 85” to enter the technical set-up environment and
carry out the calibration.
C.Er.
36
During the calibration some internal negative points have been calculated:
- the calibration point is less than the zero point.
-
the signal is negative (check the connections)
undEr
(blinking)
the weight in underload (i.e. a weight of 100 divisions below the gross zero
,
if the instrument is approved
)
i
s
notified through this message and by an acoustic signal.
oVEr
(blinking)
the weight in overload (i.e.
a
weight
of 9 divisions greater than the
capacity
)
is notified through this message
and by an acoustic signal.
ECo X
It is displayed for an instant if the master can connect to the slave X; if the connection is not possible, the
message remains fixed and the master emits an acoustic signal.