24
IP2251EN
Display Description
Selections
available
PC - Adjustment of approach speed during closing [V]
Indicates the speed from the end of the deceleration ramp to the end
of the closing stroke.
03 - Minimum
10 - Maximum
See paragraph 11.2.1
OO - Obstacle detection limit during opening [%]
Indicates the percentage of the distance travelled during
→ or after the detection of the opening limit switch →
→
on which the disengagement is deactivated.
NOTE: not active if
→ → or if → → .
99
OC - Obstacle detection limit during closure [%]
Indicates the percentage of the distance travelled during
→ or after the detection of the closing limit switch →
→
on which the reversal is deactivated.
NOTE: not active if
→ → and if → → .
99
TO - Setting motor 2 opening delay time [s]
Adjustment, in seconds, of the delay time for starting the operation of
motor 2, in relation to motor 1.
03
LR - Electric lock release time [s]
If enabled, this indicates the electric lock activation time at the start of
every opening operation with the automation closed.
1.5
M1 - Operation time - motor 1 [s]
Adjustment, in seconds, of the total operation time for motor 1.
WARNING: it is set with a sensitivity interval of 0.5s, shown
when the decimal point on the right lights up.
Example:
= 7 seconds / = 7.5 seconds
NOTE: the setting of
is only active with → → .
10
M2 - Operation time - motor 2 [s]
Adjustment, in seconds, of the total operation time for motor 1.
WARNING: it is set with a sensitivity interval of 0.5s, shown
when the decimal point on the right lights up.
Example:
= 7 seconds / = 7.5 seconds
NOTE: the setting of
is only active with → → .
10
EO - Function of output -LK+
00 - courtesy light
01 - electric lock
02 - electric lock + release stroke
03 - ON-OFF flashing light
04 - ON-OFF flashing light for LED without oscillator
05 - fixed light with internal oscillator
06 - proportional indicator light for open gate (with signal of battery operation)
07 - fixed indicator light for open gate (automation not closed)
08 - automation closed (for fail-safe electromagnets)
09 - automation open
10 - automation moving (can also be used for electromagnets that need to be powered
throughout the operation)
11 - automation opening
12 - automation closing
13 - maintenance alarm
14 - signal for batteries almost flat
ON - output always active
BA - Basic adjustment