PROGRAMMING P-SERIES
Page 23 of 78
RFRG - REFRIGERATION
This function is used to electronically control the refrigeration operations of the vender. . To enter the sub-
menu press select button 1. The following are sub-menus of the Refrigeration Menu: (TEMP)
“Temperature”, (C-F) “Celsius or Fahrenheit“, (DSP) “Display”, “Days”, (STRT) “Start”, “Stop”, (S-T)
“Storage Temperature”, (S-E) “Storage Enabled”, and (RTN) “Return”. To move to (FREE) Free Vend,
press & hold select buttons 1 & 2 simultaneously.
Press select button 1 will enter “Temperature”.
TEMP - Temperature
(Default Temperature 35
0
F/15
0
C)
This function is used to set the average product temperature for initial pull down and reload
recovery.
Press select button 1 and “tt.tx” will show on the display where x is F (Fahrenheit) or C
(Celsius) and tt.t is the degrees.
Press and hold select button 1 to increase or decrease the number by 1F or 0.5C. Release
select button with the display showing the temperature you wish to use and display will
return to “TEMP”.
Press select buttons 1 & 2 to scroll to “C” or “F”.
(C-F) - Celsius or Fahrenheit
This function is used to set the degree reading to (F) Fahrenheit or (C) Celsius.
Press select button 1 and the current setting will show on the display. Press and hold
select button 1 to toggle between F and C. Release the select button with the display
showing the setting you wish to use and display will return to “C” or “F”.
Press select buttons 1 & 2 to scroll to “DSP”.
(DSP) - Display
This function is used to enable the Temperature to be displayed following the “Ice Cold Drink”
message. “SSM” “Sales Message” must also be set to On for the temperature to be
displayed.
Press select button 1 and “DSP” will show on the display. Press select button 1 and the current
setting will be displayed (On or Off). Press and hold select button 1 to
toggle between “On” and “Off”.
Press & hold select buttons 1 & 2 simultaneously to move to the next item on the menu.
Days
This function is used to set the days of the week to use Temperature Setting Routine.
Day of Week:
(SUN) Sunday (WED) Wednesday (SAT) Saturday (RTN) Return (RTN)
(MON) Monday (THUR) Thursday (ALL) All Days
(TUE) Tuesday (FRI) Friday (NONE) No Days
Press select button 1 and “Monday #” will show on the display, where # is “0” (disable) or“1”
(enable). Press and hold select button 1 to toggle between “0” and “1”. Release the select button
with the display showing the setting you wish to use. Press select buttons 1 & 2 simultaneously
to scroll through all available days, “All Days”(ALL), “No Days”(NONE), and “Return”(RTN).
Press select button 1 at the “Return” prompt returns to “Days”.
Press & hold select buttons 1 & 2 simultaneously to move to the next item on the menu.
Start (STRT)
This function is used to set the hours and minutes for storage temperature to become active.
Press select button 1 and the current four-digit hour and minute setting will be displayed (24 hour)
Press & hold select button 1: Set Hours
Press & hold select button 2: Set Minutes
Press select buttons 1 & 2 simultaneously to move to the next item on the menu.