Digital Monitoring Products, Inc | 9000 Series Installation and Programming Guide 20
Site Code Position and Length
Enter the site code start position and length in the data string.
Press select area 2 to clear the site code start position and
enter a number between 0-255. Press CMD to save. Default is
1.
Press select area 4 to clear the site code length and enter a
number between 1-24. Press CMD to save. Default is 8.
User Code Position and Length
Define the user code start bit position and length. Press select
area 2 to clear the user code position and enter a number
between 0-255. Press CMD to save. Default is 9.
Press select area 4 to clear the user code length and enter a
number between 16-64. Press CMD to save. The default is the
DMP value of 16.
SITE CODE
POS: 1 LEN: 8
USER CODE
POS: 9 LEN: 16