9000 Series Installation and Programming Guide | Digital Monitoring Products, Inc. 35
COMPATIBILITY
Panel Models
All DMP panels and 1100 Series Wireless Receivers are compatible with the 9000 Series.
Wireless encryption requires keypad firmware Version 300 or higher and panel firmware
Version 183 or higher.
Public Card Formats
CARD FORMAT
WIEGAND
CODE LENGTH
SITE CODE
POSITION
SITE CODE
LENGTH
USER CODE
POSITION
USER CODE
LENGTH
USER CODE
DIGITS
H10301 26-Bit 26 1 8 9 16 5
H10302 37-Bit w/o FAC 37 0 1 1 35 11
H10304 37-Bit w/ FAC 37 1 16 17 19 6
Farpointe 39-Bit 39 1 17 18 20 7
Corporate 1000 35-Bit 35 2 12 14 20 6
Corporate 1000 48-Bit 48 2 22 24 23 7