PROGRAM THE PANEL
Before continuing with programming and setup, program the keypad in the panel as a device.
To access the Programmer menu, reset the panel by shorting the RESET header, press Keypad in the Carousel menu,
enter 6653 (PROG), then press CMD.
After completing each of the following steps, press CMD to advance to the next option. To exit the Programmer menu,
tap CMD to advance through the menu items until you reach the end of the menu. At the end of the menu, press the
back button twice to return to the main screen. Refer to the panel programming guide as needed.
Network Options
Network Options
Advance to Network Options, then press a select area to enter the setup menu.
Local IP Address
Enter the local IP address for the panel. The local IP address must be unique and cannot
be duplicated. The default address is 192.168.0.250. This must match the Panel IP
Address in keypad Network Options.
734N Listen Port (XR Only)
Enter the port number the panel will use to send communication to the keypad via
Wi-Fi. The default port is 2002. This must match the Panel Port in keypad Network
Options.
734N Passphrase (XR Only)
Enter an 8 to 16 charcter passphrase for the panel to use to send communication to the
keypad via Wi-Fi. The default passphrase is blank. This must match the 734N Passphrase
in keypad Network Options.
Programming Port (XT/XTL Only)
Enter the port number the panel will use to send communication to the keypad via
Wi-Fi. To connect one Wi-Fi keypad, leave the Programming Port at the default setting.
If you want to connect up to three Wi-Fi keypads, set the Programming Port to 0. The
default port is 2001. This must match the Panel Port in keypad Network Options.
NETWORK OPTIONS
LOCAL IP ADDRESS
192.168.0.250
PORT: 2002
734N PASSPHRASE
-
PROGRAMMING PORT
2001

Table of Contents