TROUBLE SHOOTING (Continued....)
SLUGGISH HYDRAULIC OPERATION
1. Check for low hydraulic system pressure or low
reservoir level.
2. Check for air in the hydraulic system.
3. Check for a blocked or clogged hydraulic lter.
4. Check for faulty hydraulic pump operation.
5. Check for cold hydraulic oil.
BAND DRIVE TRANSMISSION GETS HOT
1. Check for low transmission uid level.
2. Check for lubricant leakage.
NUISANCE OVERLOAD TRIPPING
1. Check to see if the overload relays are set too low.
Increase the setting if necessary.
SENSING ARM HANGS UP
1. Check to see if the sensing arm is dirty.
MALFUNCTIONING OPERATING SEQUENCE
1. EPROM memory pack is malfunctioning, or is not
installed or is installed incorrectly.