Disposal Water Heater
• Listen for a change in burner sounds or look for
changes in flame appearance from a hard blue flame
to a so lazy flame or one that is very yellow. These
are indications of an obstruction in the burner tube or
the burner assembly.
• Confirm the flame spreader is in alignment. The flame
spreader should be straight and in the middle of the
burner tube, allowing for an even flame.
• Make sure the U-tube is not blocked or collapsed.
Clear any blockages, if present.
9.6 Understanding P/T Valve
Weeping
A P/T relief valve dripping while the Water Heater is
running does not mean it is defective. During normal
expansion of water, the P/T relief valve is heated in the
closed water system of an RV. This may cause the P/T
relief valve to drip.
9.7 Resetting a Locked-Out Control
I
Gas/Electric Combination (Standard and EXT)
Models Only
When the electric element switch is turned to the On
position, the relay closes and passes 110 VAC to the
element. If the thermostat fails, the E.C.O. opens and
locks out the system. To correct, check the E.C.O to
assure good contact with the tank. Reset the control by
turning the electric switch to the Off position then to the
On position.
10 Disposal
M
Place the packaging material in the appropriate
recycling waste bins, whenever possible. Consult
a local recycling center or specialist dealer for
details about how to dispose of the product in
accordance with all applicable national and local
regulations.
11 Replacement Parts
For the most current parts information, visit www.
dometic.com.