- 15 -
LOW PRESSURE RESTART
This function is included only in commercial (C-) models.
In commercial applications it is common that the water purier operates automati-
cally towards a connected external equipment. An alarm stop may cause troubles
before it is noticed by the user.
The reason for the alarm is sometimes a temporary pressure drop in the inlet water
pressure. Examples could be roadwork, momentaneous high water consumption
near the the installation, mistake by a co-worker to close the water supply etc.
The purpose of this function is to avoid these unnecessary alarms, and allow the
product to automatically restart after an alarm from low inlet pressure.
The water purier will make three attempts to restart: After 3 minutes, 20 minutes
and nally 4 hours. If the pressure is not sufcient after three attempts the water
purier stop permanentely.
not help.
INDICATION FAULT CASE REMEDIAL ACTION
Only included in commercial (C-)
models.
The product has stopped due to low
inlet pressure detected by the inlet
pressure sensor.
The system is idle waiting for auto-
matic restart.
Attend the problem according to the
“TROUBLESHOOTING” guide.
Press and hold the ‘calibration’ but-
ton until the warning lights goes out,
and the product will restart.
Diods for ‘lter I’ and ‘stop’ blinks alternately.
Slow ‘lter I’
Quick ‘stop’
Awaiting 1st restart
(after 3 minutes)
Medium ‘lter I’
Medium ‘stop’
Awaiting 2nd restart
(after further 20 minutes)
Quick ‘lter I’
Slow ‘stop’
Awaiting 3rd and last restart
(after further 4 hours)
Low pressure stop (same indication
for all models).
In commercial (C-) models this
means that the product has made
three unsuccessful restart attempts.
PRODUCT DESCRIPTION
-
be removed when the product is
idle in restart mode.