- 19 -
TROUBLESHOOTING
INDICATION FAULT CASE REMEDIAL ACTION
Warning about used lter. Change lter II in accordance with • REPLACING
THE FILTERS.
See “• FAULT IDENTIFICATION TABLE”, section 9.
Alarm for poorer water quality. If the water purier is new and not yet calibrat-•
ed, rectify according to the section CALIBRA-
TION.
Pull out and reconnect the plug so that the water •
purier ushes. Repeat this procedure two or
more times.
See “• FAULT IDENTIFICATION TABLE”, section 6.
Alarm indicating that calibration has been
commenced, but not carried out correctly
(probably due to the tap having been closed
before 10 minutes had elapsed).
Restart the water purier by pulling out and •
reconnecting the plug so that ushing is per-
formed. Recalibrate the water purier according
to the section CALIBRATION.
See “• FAULT IDENTIFICATION TABLE”, section 4.
Alarm for fault in the water quality meter.
Restart the water purier by pulling out and •
reconnecting the plug so that ushing is per-
formed. Wait for 2 hours then use the water
purier as normal.
See “• FAULT IDENTIFICATION TABLE”, section 4.
Warning that the tap has been on for more than
15 minutes without a pause, and that the prod-
uct has shut down automatically as a result.
Turn off the tap and leave the water purier •
undisturbed for at least 30 minutes.
Restart the product by disconnecting and then •
reconnecting the electricity.
After automatic ushing the water purier will •
be ready for use again.
See “• FAULT IDENTIFICATION TABLE”, section 4.
The membrane may have become blocked. Clean the water purier in accordance with •
“CLEANING/DESCALING”.
The water pressure between the water purier
and e.g. tap, valve or tank has dropped below
the water purier’s starting pressure level.
Check the connections.•
Check that the ends of the water puried water •
hose are at, circular and with no burrs.
Check that taps and valves are watertight in their •
closed position.
Unpleasant odour When the water purier is stationary (without
power supply) and there is microbiological
growth in the water, the water can smell “bad”.
Try ushing the water purier according to the •
section FLUSHING.
Clean the water purier in accordance with •
DISINFECTION.
If the water purier has experienced an emergency stop: Restart by pulling out the plug, wait for at least one minute and then,
reconnect the plug again.