- 30 -
Symptom
Possible error
codes
Check/Action Remedy

Water is not produced.
There is rattling
sound from the
motor.
Water is produced.
Normal vibrations
during operation or
ushing (when built-
in or in Domestic
installations.)
20
Low inlet pressure.
21
Loose driving belt.
Vibrating hoses or
something in contact
with rotating parts.
Damaged ball
bearings in the
motor.
Does the motor rotate
properly or has it stopped
(vibrating/rattling)?
Noticeable sound during
water production or during
ushing.
Is inlet pressure sufcient?
Is the inlet pressure sensor
working?
Check driving belt.
Check internal parts. Make
sure nothing is in contact
with the cooling fan for the
motor or the driving belt.
Does the sound appear from
the motor?
Noticeable resistance or
sound when the motor axis
is turned by hand?
The circuit board is broken and cannot make
the motor turn properly – change circuit board.
Decrease the sound by placing the product on
a thin rubber mat (few millimetres).
Measure the inlet pressure and adjust if
necessary.
Tighten or loosen belt depending on status.
Change motor.
TROUBLESHOOTING
a)
b)
c)
d)
a)
e)