o Within the first 2 minutes after powering the dryer, if the low and high temperature keys are pressed
together for 10 seconds, the accumulated balance will reset to 0. If these keys are pressed together
after the 2 minutes, it will not have any effect.
• Parameter edition: it is possible to modify certain operating parameters of the control using the
ELECTRONIC CONTROL console (sold separately).
4.3. How to run a drying cycle
• OPL Mode:
When the machine is in WAIT mode, proceed as follows:
1. Select the required drying time using the time increase/decrease keys. The default time selected
is 40 minutes.
2. Select the required drying temperature using one of the 3 temperature keys. The default
temperature selected is Medium.
3. Press START/STOP keypad to start the drying cycle.
4.4. ALARMS AND WARNINGS
The open door and open filter alarms lead to the pausing of the current programme. When the conditions
triggering the alarm disappear, the drying cycle can be restarted as soon as the alarm is removed. The other
alarms stop the programme, and a warning alarm is heard. This warning is stopped by pressing Start/Stop
or by removing the reason for the alarm.
When any of these alarms is triggered: AL-3, AL-4, AL-6 or AL-9, the machine enters an alarm mode which
permits a progressive reduction of the internal temperature of the dryer and the fabrics to prevent damage
to the materials and prevent burns. This cooling lasts 10 minutes. After this time the machine stops but the
alarm remains on until it is duly cancelled. The cooling can be cancelled by pressing Start/Stop.
Before starting the machine, an initial check of the alarms AL-1, AL-2, AL-3, AL-5 and AL-9 is made. If any
of these are on, the machine cannot be started.
The following table lists the different alarms and warnings and their possible solutions. They are indicated
via a code of red flashes on the Start/Stop LED light. To determine the alarm number, count the number of
short flashes of the LED. The cycle is repeated after a long flash.
* Close the filter cover.
No flame (only for
gas-heated versions)
* Check gas supply cock open.
* Check that the pressure is correct.
To “RESET” the gas module, press the time
increase and decrease keys together when the
alarm is active.
Pressure drop failure
or insufficient air
flow.
(Not available in
professional
heaters)
* Check that the outlet conduit is free, check that it is
not too long.
* Check that the filter is fluff-free.
* Check that the fan's turbine is fluff-free.
* Check that the outlet conduit is correctly connected
and does not have a free outlet.
Excess temperature
in the system –
safety thermostat
* Check that the air flow is correct.
* Check gas pressure is correct (only gas heating).
If any of the previous alarms were to persist, consult your Technical Assistance Service. Always notify
the machine's serial number for your queries.