ES 200
81
DEEN
Error messages appearing on the PDA are explained in the instructions “ASP for ES 200”
Meaning of display codes
Message Error Method of acknowledgement
No error in memory
Obstruction Self-knowledgement
Locking device Turn program switch to OFF
Program switch Turn program switch to OFF
Light barrier Turn program switch to OFF
Incremental encoder Turn program switch to OFF
Rechargeable battery pack Turn program switch to OFF
System, relay test Power reset required
EMERGENCY OFF activated Release EMERGENCY OFF pushbutton
Learning cycle parameter error Turn program switch to OFF
Motor fault Self-knowledgement
No rechargeable battery pack detected
during battery test: Reset via control unit Turn program switch to OFF
Force test
"No rechargeable battery" mode: Turn program switch to OFF
EMERGENCY OPEN mode: wait until force test in “open” position is "OK"
Overcurrent at motor for more than 30 sec Turn program switch to OFF
Commissioning error During commissioning (first cycle), the door opens
Change rotation direction of motor
Press During the cycle
Additional error cisplay on PDA
Locking device
Program switch
Rechargeable battery pack
System
Motor
Error during test of rechargeable battery pack
Force test
Overcurrent
DCW
15, 16, 23
22
28
21
10
11
12
13
15, 29