EasyManua.ls Logo

Dormakaba ES 200 - Commissioning

Dormakaba ES 200
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ES 200
26
DEEN
1. Commissioning
1.1 Please note:
Work on electrical equipment may only be performed by
properly qualified electricians.
Power supply (by others) with 16 A fuse protection must be
available.
Power cord must be double-insulated, for example:
NYM. Do not use flat webbed house wires!
The maximum cable length of the external components must
not exceed 30 m.
1.2 Basic requirements:
The operator is fully assembled.
The protective earth (PE) is connected.
The safety sensors are connected.
Components supplied separately, such as program switches,
activators, radar motion detectors, Night-/Bank
keyswitches and EMERGENCY OFF pushbuttons are
installed and connected.
The end stops are adjusted so that both active panels touch
the end stops when the panels have reached maximum
opening width.
When the door is closed, the active and the passive door
panel must not collide with the sealing profiles.
The door has to run smoothly. Check the length of the
connection screws of the toothed belt and replace the
screws if necessary.
Update (small motor)
The ES 200 control unit can be installed as a replacement for
older systems with GR 63x25 motors. However, a special
cable for the incremental encoder with a pulse devider is
required.
The following procedure has to be observed:
- Install hardware.
- Set program switch to ”OFF” and activate the
EMERGENCY OFF pushbutton.
- Reset system to original settings (factory settings):
Press and hold service key, switch on power supply.
- Release the service key as soon as the 8 on the seven-
segment display blinks twice.
- Adjust the GR 63x25 Motor via the pushbuttons on the basic
module (b = 0) or via PDA.
- Unatch the EMERGENCY OFF pushbutton.
- Perform a learning cycle.
Safeguarding of door:
The safety measures to safeguard the doors must be made in
accordance with the local (countryspecific) regulations.
Where sliding doors shall be operated in Germany according to
DIN 18650 (German Industrial Standard), the specifications
stated in this industrial standard must be observed.
See: WN 057015 45-5-32
1.3 First Commissioning
1.3.1 Open the sliding panels half way.
1.3.2 ES 200
Easy
:
• Set program switch to AUTOMATIC
ES 200 / ES 200-2D:
• Set program switch to OFF
1.3.3 Unlatch the EMERGENCY OFF pushbutton and bridge
the light barriers. During the first commissioning of the system
the infrared light curtains or light barriers shall be replaced by
jumpers.(See connection diagram 056632-45532) Following
the learning cycle, the first closing cycle and the
parameterization of the control unit, the infrared light curtains
or light barriers have to be connected and checked for proper
functioning.
1.3.4 Insert the power plug and connect immediately
thereafter the rechargeable battery pack. (within max. 8 sec.)
The door must perform a closing cycle at low (creep)
speed.
If the door performs an opening cycle, the system must
be set back to original settings.
Disconnect the power plug so that the opening cycle
stops.
Proceed on 2. original settings
If the door performs a closing cycle, proceed with the learning
cycle starting with the door closed.
Please note:
The light barriers and radar motion detectors are disabled
during the learning cycle, as it has to be performed without
interruptions.
In case that a fault or error should occur during this
procedure, the learning cycle will be interrupted and needs to
be started anew.
1.3.5 Performing the learning cycle:
ES 200
Easy
:
press and hold SELECT button for 3 sec. Then the door will
perform a learning cycle.
ES 200 / ES 200-2D / ES 200 CO48 / DAC 300:
press SERVICE button.
Press and hold SERVICE/SELECT button until the door
commences with the learning cycle. The external segments
of the 7-segment display will illuminate in turn.
The door accelerates in order to determine the door weight.
The door opens at low (creep) speed to determine the
opening width.
EN