ES 200
3333
DEEN
4. Care and maintenance
The unit must be checked and, if necessary, serviced
before it is commissioned for the first time and
thereafter as required, but at least once a year – FST
units twice a year - by a specialist engineer or by
authorised specialist personnel.
The guidelines for power-operated windows, doors and
gates, according to BGR 232 (Federal Bureau for
Geology and Commodities) must be complied with.
For FST units also the German guidelines for
automatic sliding doors with application in escape
routes (AutSchR) must be complied with.
Wear parts
The following wear parts must be checked in regular
intervals and replaced if required in order to ensure
the smooth function of the unit.
• Track rollers: every 2 years
• Rubber end stops: at every service check
• Track rail: every 5 years
• Toothed belt: every 1,000,000 opening/closing cycle
• Floor guides: at every service check
• Brushes (optional)
• Battery pack ES200 complete, Order No. 04000160
Replacing the battery
Always note the warning on batteries.
Use only recommended batteries approved by DORMA.
The battery may be replaced only by qualified persons.
Please refer to the installation manual.
The removal of the battery pack is carried out in the reverse
order of the installation manual.
ES 200 CO48
The rubber belt with the order number
9925528101150 has to be replaced every year.
DAC 300
The rubber belt has to be replaced every year.
We would recommend to conclude a maintenance
contract with DORMA.
Please contact your supplier or
call the following number in Germany
+49 (0) 2333 - 793 – 0
Further information on the internet:
http://www.dorma.com/en/
Service/
contact our regional offices
Africa
Asia
Australia
Europe your country
Middle East
North America
South America
Cleaning
During cleaning, the program switch must be set to
OFF or PERMANENT OPEN in order to avoid
inadvertent movements of the door. The whole of the
sliding door unit (aluminium, glass, covers) can be
cleaned with a damp cloth and normal commercial
detergents. The light barriers have to be cleaned with
a dry cloth and the floor guide rails must be cleaned.
ES 200 / ES 200-2D / ES 200 CO48 / DAC 300:
Service display
The service display informs the facility operator that
the door system has to be serviced.
The maintenance intervals can be adjusted via PDA.
Either a time slice (monthly interval, e.g. every 6
months) and/or a certain number of opening/closing
cycles can be selected (e.g. following 80,000 opening/
closing cycles).
Depending on the selected interval, the service display
blinks as follows:
Max. number of adjusted opening/closing cycles reached:
• Display illuminates permanently.
Time interval expired:
• Display blinks (every 0.5 seconds).
Time and opening/closing cycle interval reached:
• Display illuminates permanently for 10
seconds, then it blinks for 10 sec.
Test cycle
NOT for ES 200 Easy!
With the aid of the PDA, a test cycle may be performed in
order to optimise the smooth performance of the door.
Check Up
• Derailment guard/ counter roller adjusted correctly (0.5
mm)?
• Door panels run smoothly, no grinding noise?
• Electromechanical locking adjusted correctly (> 1mm)?
• All shortened wires provided with end splices?
• All connectors plugged in?
• All cables fixed / no obstacles within the driving phase?
• Only for ES 200 with "Emergency opening function”.
• Serial connection with "internal sensor” performed?
Briefing
Following successful commissioning and functional testing
of the unit, the documentation has to be handed over to the
facility operator and a briefing has to be made.