USER ERRORS LIST CAUSES/ACTIONS
3488
SHUTTER IS NOT OPEN.
PRINT IS NOT POSSIBLE
The shutter is blocked in close position or damaged :
Check wiring or Change the shutter Assy.
I/O board is damaged and does not send the signal to
the shutter :
Change the industrial interface board
3489
ERROR IN SHUTTER STATUS. OPEN
STATUS BIT = CLOSE STATUS BIT
Shutter is closed : Turn on the shutter key
3490
ERROR IN LASER STATUS
Laser is warming up : wait the status “Laser is OK”
3491
ERROR IN TEMPERATURE STATUS
Temperature of the source is not in the nominal range.
3492
ERROR LASER OVERTEMPERATURE
Laser source exceed the limit temperature (55°C) :
Use a cooling system to decrease the temperature.
Laser fans are not running : Check presence of 24V or
change them
3493
ERROR. THE USER MUST REARM THE
LASER
Interlock or emergency stop must be deactivated and
key switch must be OFF and ON.
3494
ERROR. LASER AUTOCHECK
Laser is warming up, wait the status “Laser is OK”
3495
ERROR. LASER NOT READY
Laser is warming up, wait the status “Laser is OK”
3496
ERROR. LASER OFF. TURN ON / REARM THE
LASER KEY
Turn On the power key
3497
ERROR THE EMERGENCY INTERLOCK IS
PUSHED
Safety interlock loop opened : Close interlocks
3498
ERROR.EXTERNAL INTERLOCK /
EMERGENCY STOP ACTIVATED
External Interlock is open
Emergency stop button is activated
External emergency stop is activated
Wire on Industrial Interface board is unplugged or not
present.
3499
ERROR FUME EXTRACTOR PRE-CLOGGED
Pipes may be partially obstructed :
The pre-filter is partially obstructed (clogged @75%)
The main filter is partially obstructed (clogged @75%)
3500
ERROR FUME EXTRACTOR CLOGGED
Pre-filter or Combined filter is obstructed :
Stop the printer + Extractor, replace the pre-filter and re-
start the printer. If the alarm remains replace the main
filter
After replacement, do an auto flow reset.
3501
ERROR COOLING DEFAULT
Cooling flow alarm input activated : start the cooler
3502
ERROR TIME COUNTER OVERFLOW
Counter reach the final value : reset counter or increase
max value
3503
ERROR. PRODUCT COUNTER OVERFLOW
Counter reach the final value : reset counter or increase
max value
3504
ERROR METER COUNTER OVERFLOW
Counter reach the final value : reset counter or increase
max value
1506
MARK FIELD OUT OF THE PRINT AREA
Move the field in the marking area or reduce the fiel size