Troubleshooting
A70622-D1
155/192
SPS Upgrade From safety level PLc to PLd 1 / 2
Special Tools
Allen Key 2mm
Prerequisite
Switch off the laser/Unplug from the mains supply
Remarks
According to TB121201
1
Unplug: the ribbon cable (A), both white
connectors (B) and the USB con
nector (C)
localized behind the ribbon cable.
2
Unscrew the four (4) CHC screws which
maintain the board on the electronic plate.
Disconnect the scanalone board from the
industrial interface board.
3
Replace the standard industrial inter
face board
by the
optional board ENM70867 dedicated for
PLd safety level
4
Connect wires (x2) from switch (NC contact) to
“INTSTOP “and “MIN1” of J2 board connector.
Connect the power supply of the switch to the
pin 14 (+24V).
5
Software settings: installation of software
version LO5.7 or higher is required. The level is
selected using the menu advanced
settings/Safety. By default, the level is the
standard PLc.
Select PLd.