Loading...
Battery can explode if mistreated. Do not recharge, disassemble or dispose of
in fire.
The battery used in this device may present a risk of fire or chemical burn if
mistreated. Do not disassemble, heat above 100°C or incinerate.
Dispose of used battery promptly. Keep away from children. Do not
disassemble and do not dispose of in fire.
The console can remain energized via the backup battery, even though the
line power has been removed.
The inside of the console contains high-voltage circuitry; ONLY certified
technicians should be permitted access to the console.
An external disconnect device must be installed for any permanently
connected equipment!
An electrical outlet must be installed near any equipment requiring access
through a plug connection!
The console has one (1) lithium battery. When the battery can no longer hold sufficient electrical power it
must be replaced.
IMPORTANT: Replace the battery with a recommended replacement ONLY. Use of a
different battery can cause a risk of fire or explosion.
A used battery must be removed from the console. Used batteries must be moved to a battery-recycling
center for approved disposal.
8.5 Compatible Devices
The devices shown below can be connected to the ISB-1W I.S barrier that iscontained in the console:
l 924B probes
l DMP 1-wire probes
l Smart sensors
8.6 Device Connections to the ISB-1W Internal I.S. Barrier
The ISB-1W 12V I.S (Intrinsically Safe) barrier has four channels where probes and sensor can connect.