DMP Probe with ProGauge Floats
The DMP probe is shipped fully assembled. You can skip to step 4 to install an assembled probe. If it
becomes necessary to disassemble the probe components, use steps 1-3 below to assemble the floats and
end cap to the probe before you continue.
1. Put the Product Float on the probe shaft. Make sure the magnet side points toward the bottom of the
probe shaft for FMS Floats. Make sure the arrow points toward the probe head for ProGauge floats.
2. Put the Water Float on the probe shaft (if applicable). Make sure the magnet side points toward the
bottom of the probe shaft for FMS Floats. Make sure the arrow points toward the probe head for
ProGauge floats.
3. Attach the End Cap to the end of the probe shaft. Turn it clockwise to tighten.