Use Instructions for NIOSH-approved full facepieces 9
After use
Follow ISO 2230 and national regulations concerning storage,
cleaning and maintenance of rubber products.
Recommended inspection and maintenance
intervals
Observe national guidelines if applicable.
Type of work to be
performed
prior to use
after use
half-yearly
every 2 years
every 4 years
every 6 years
Check by wearer
X
Clean and disinfect
XX
1)
1) for gastight packed facepieces, otherwise every 6 months
Visually inspect, check
correct function and leak
tightness
XX
2)
2) for gastight packed facepieces every 2 years
X
Replace exhalation valve
disc
X
Replace O-ring and speech
diaphragm
X
Cleaning and disinfecting
WARNING
The facepiece body must be cleaned thoroughly so that no residues
from skin care products remain on it.
Otherwise the elasticity in the sealing area can be lost and the
facepiece will no longer fit correctly.
If this warning is not heeded, poisoning or death can result.
CAUTION
Do not use any solvents (e.g. acetone, alcohol) or cleaning agents
containing abrasive particles for cleaning and disinfecting. Only use
the methods and the approved cleaning and disinfecting agents
described in this section. Other methods or agents can cause
damage to the product. Undiluted agents that come into direct
contact with eyes or skin are hazardous to health. Always wear
suitable protective equipment when working with the cleaning and
disinfecting agents described in this section.
NOTICE
Since the use of certain cleaning and disinfecting agents is not
allowed among all countries, Dräger tested and recommends
several cleaning and disinfecting agents. However, Dräger makes
no representations that such agents comply with or are approved
for use in your specific country’s regulations. Make sure to follow
the procedure that is suitable for your country.
For further information please contact Dräger or your local dealer.
9021721_5.book Seite 9 Donnerstag, 21. Mai 2015 11:44 11

Table of Contents

Other manuals for Dräger FPS 7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dräger FPS 7000 and is the answer not in the manual?

Dräger FPS 7000 Specifications

General IconGeneral
Visor MaterialPolycarbonate
Facepiece MaterialSilicone or EPDM
ApprovalEN 136 class 3
TypeFull-face mask
StandardsEN 136 Class 3