EasyManuals Logo

Dräger HFG 000 Series Instructions For Use

Dräger HFG 000 Series
Go to English
314 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #46 background imageLoading...
Page #46 background image
 ,QVWUXFWLRQVIRUXVH_ X-am
®
8000
en_ Operation
2. Select and confirm the desired feature.
4.9 Opening information
1. Select > Status in measuring mode.
The following options are available:
4.10 Pairing a gas detector with a
smartphone
The Bluetooth
®
feature may only be used in
countries for which an approval exists and is not part of
the certified measuring function. Contact Dräger if there
are any questions about availability.
The gas detector can be paired with a suitable
smartphone via Bluetooth in order to use the optionally
available Dräger CSE Connect app.
For detailed information on pairing via Bluetooth
®
, also
refer to the instructions for use of the smartphone used.
Contamination of the gas detector or shielding
elements (e.g. protective cover or CSE case) can
reduce the Bluetooth
®
range.
Option Description
Messages The pending warnings and
errors are displayed. For a
description of the mes-
sages and remedial mea-
sures, see the technical
manual.
Device information Device information and
information about the
Bluetooth® module
(optional, X-am 8000 only)
is displayed (e.g. MAC
address, serial number,
firmware version etc.).
Gas statistics The following gas statis-
tics are available:
Select Shift peak to
display the exposure
peaks for all gasses.
Select Application
peak to display the
application peaks for
all gasses.
Select TWA values to
display the available
TWA values for all gas-
ses.
Select STEV values to
display the available
STEL values for all
gasses.
Intervals The following intervals are
available:
Select the bump test
interval (Bumptest
interval) (if configured)
to display the days
remaining until the next
bump test for all chan-
nels. For details, select
and confirm the
respective channel.
Select Calibration
interval to display the
days remaining until
the next calibration for
all channels. For
details, select and con-
firm the respective
channel.
Select User life time
to display the remain-
ing service life.
Capture ranges Capture ranges are dis-
played (if configured).
Battery The battery state of
charge is displayed
(large).
Approvals
(X-am 8000 only with the
Bluetooth® module)
Approval information is
displayed (e-Label).
Option Description

Table of Contents

Other manuals for Dräger HFG 000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dräger HFG 000 Series and is the answer not in the manual?

Dräger HFG 000 Series Specifications

General IconGeneral
BrandDräger
ModelHFG 000 Series
CategoryGas Detectors
LanguageEnglish

Related product manuals