Faults, Cause and Remedy
201 The zero point calibration of
the DrägerSensor CatEx 125
is not valid
Carry out the fresh air
calibration, page 35.
202 The span calibration of the
DrägerSensor CatEx 125 is
not valid
Carry out the span calibration,
page 37 or page 39.
203 The measurement value of the
DrägerSensor CatEx 125 is in
the negative range
Carry out the fresh air
calibration, page 35.
204 The DrägerSensor CatEx 125
is not inserted
Check the DrägerSensor CatEx
125, page 45.
205 Error during the function test
with gas (bump test) of the
DrägerSensor CatEx 125
Repeat the function test,
calibrate or replace the
DrägerSensor CatEx 125, if
necessary, page 45.
206 Function not possible:
O
2
deficiency
Use DrägerSensor CatEx 125 in
atmospheres with more than
10.0 % O
2
by vol..
302 The span calibration of the
DrägerSensor XXS O
2
is not
valid
Carry out the span calibration.
page 39 or carry out the fresh air
calibration, page 35.
304 The DrägerSensor XXS O
2
is
not inserted
Check the DrägerSensor XXS
O
2
, page 45.
305 Error during the function test
with gas (bump test) of the
DrägerSensor XXS O
2
Repeat the function test,
calibrate or replace the
DrägerSensor XXS O
2
if
necessary, page 45.
401 The zero point calibration of
DrägerSensor XXS H
2
S is not
valid
Carry out the fresh air
calibration, page 35.
402 The span calibration of the
Dräger Sensor XXS H
2
S is not
valid
Carry out the span calibration,
page 39.
403 Measured value of the
DrägerSensor XXS H
2
S is in
the negative range
Carry out the fresh air
calibration, page 35.
Special symbol » « and
displayed numerical code:
Cause Remedy

Table of Contents

Other manuals for Dräger X-am 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dräger X-am 2000 and is the answer not in the manual?

Dräger X-am 2000 Specifications

General IconGeneral
BrandDräger
ModelX-am 2000
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals