6
Tests and Approvals
Tests and Approvals
Marking
X-am 1100, 1700 and 2000; approved as type LQG 00xx
0158
I M2 / II 2G
Ex ia d I/IIC T4/T3
DEMKO 06 ATEX 06.140055X
IECEx ULD 06.0001X
Um = 4.6 V, Im = 1.3 A
Only as to intrinsic safety for use in haz. loc.
Intrinsically safe / Securite Intrinseque Ex ia
Class I&II, Div. 1, Gr. A,B,C,D,E,F,G TC T4/T3
–20
o
C
≤
Ta
≤
+50 / +40
o
C
Temperature class and ambient temperature: refer to the power pack!
Dräger Safety, 23560 Lübeck, Germany
Serial no.
*)
Power pack 83 18 703; approved as type ABT 0000
Temperature class T4
–20
o
C
≤
Ta
≤
+50
o
C
use with alkaline batteries
Energizer No. E91
Energizer No. EN91 (industrial)
Varta Type 4106 (power one)
Temperature class T3
–20
o
C
≤
Ta
≤
+40
o
C
use with NiMH batteries
GP 180AAHC (1800 mAh)
Power pack 83 18 704; approved as HBT 0000
Temperature class T4
–20
o
C
≤
Ta
≤
+50
o
C
ATTENTION:
Read the safety measures in the Instructions for Use.
Do not replace or charge batteries in potentially explosive areas.
*)
Year of construction is coded by the third capital letter of the serial number: T = 2003, U = 2004, W = 2005,
X = 2006, Y = 2007, Z = 2008, A = 2009, B = 2010, C = 2011, etc.