DRAMIŃSKI iScan mini user guide
30
16. Technical specication
Dimensions 140 x 170 x 52 mm (width x height x depth)
Weight of the device 1350 g with the probe and the battery
Weight of the battery 292 g
Purpose
Ultrasound diagnostics of farm animals:
Diagnostics of the reproductive tract
Confirmation and monitoring of pregnancy
Determination of sex of foetus
Determination of age of foetus
Measurement of backfat thickness
Ultrasound examination of the lungs
Uses other than specified above are not excluded
Image display modes
Screen
Goggles
Image rotated by 90°
Image rotated by 180°
Image refreshing Up to 58 FPS
Greyscale 256 shades
Gamma 10 settings
Display screen
5.0” diagonal
IPS LCD LED
500 cd/m
2
480 x 800 px
Probe
Electronic, broadband
7 MHz, 60 mm.
Method of connecting a probe Permanent
Keyboard Membrane, water resistant
Imaging mode
B Mode
B+B Mode
Image management
Freezing the image
Dimensioning
Zoom 100–160% at 20% increments
Saving to internal memory
Exporting to external storage device
Exporting to mobile devices with the use of WiFi
Measurements
Distance
Follicle (automatic)
Area (from 2 measurements)
Saving data to the memory
Image with measurements
Cine loop (max. 512 frames)
Image memory 200
Cine loop memory 200
Data transmission
USB-C
WiFi (to Draminski App)