Section 5: Programming
When the Delinquency option is on, this code is transmitted when no zone activity has been detected on the system for the
number of hours programmed in Delinquency Transmission Delay.
7 Self Test Trouble
Sent when a self test trouble occurs for an outdoor PIR.
8 Self Test Trouble Restore
Sent when a self test trouble has been restored for an outdoor PIR.
[312] Maintenance Events 2
1/2 Installer Lead In/ Lead Out
The Installer Lead In and Lead Out reporting codes are sent when the alarm system enters and exits Installer Programming
respectively.
When Installer Programming is automatically exited after PC-Link is activated, the Installer Lead Out event is not com-
municated until after the DLS session is complete.
3/4 DLS Lead In/Lead Out
The DLS Lead In reporting code is sent:
l after DLS communication has been successfully established, but before the alarm system calls back the down-
loading computer. This code is only transmitted when call back is enabled.
l on user-initiated call-up.
The DLS Lead Out reporting code is sent when a DLS session is successfully ended.
Note: If DLS is terminated by an alarm, the DLS Lead Out reporting code is not transmitted.
5/6 SA Lead In/Lead Out
The SA Lead In reporting code is sent:
l after SA communication has been successfully established, but before the alarm system calls back the downloading
computer. This code is only transmitted when call back is enabled.
l on user-initiated call-up.
The SA Lead Out reporting code is sent when an SA session is successfully ended. The SA Lead Out reporting code is still
sent if the session is terminated by an alarm.
7 Event Buffer 75% Full
Sent when the event buffer reaches a threshold of 75% without being uploaded.
[313] Maintenance Events 3
1/2 Firmware Update Begin/was Successful
Sent when a remote firmware update is initiated/ is successfully completed.
3 Firmware Update Fail
Sent after an unsuccessful remote firmware update.
[314] Maintenance Events 4
1/2 Gas Trouble/Restore
Sent when a trouble occurs or is restored on a wireless gas detector.
3/4 Heat Trouble/Restore
Sent when a heat trouble occurs or is restored on a wireless temperature detector.
5/6 Freeze Trouble/Restore
Sent when a freeze trouble occurs or is restored on a wireless temperature detector.
7/8 Probe Disconnected Trouble/Restore
Sent when a probe disconnected trouble occurs or is restored on a wireless temperature detector.
[321] Receiver Events
2/4/6/8 Receiver 1 - 4 FTC Restore
Sent when the panel detects an FTC trouble.
- 104 -

Table of Contents

Other manuals for DSC HS2016

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC HS2016 and is the answer not in the manual?

DSC HS2016 Specifications

General IconGeneral
Mounting TypeWall mount
Power Supply16.5VAC
Battery Backup12VDC
Operating Temperature32°F to 120°F (0°C to 49°C)
Dimensions267mm

Related product manuals