Section 5: Programming
[04] Receiver 4
[002] Test Transmissions
These options control which receiver paths are enabled for test transmission events. To assign a test transmission event to a
receiver, select from the following list:
[01] Receiver 1
[02] Receiver 2
[03] Receiver 3
[04] Receiver 4
[310] Account Codes
These programming sections are used to set the system and partition account codes.
[000] System Account Code
The system account code is used to identify the alarm system when communicating system events to the central station. The
system account code can be either 4 or 6 digits long. Program a 6-digit code only when using the SIA reporting format. SIA
uses this account code for all partitions and system events. All other reporting formats use a 4-digit system account code to
report system maintenance (e.g., low battery, zone fault) and test transmission events. To program a 4-digit code, add FF to
the last two digits.
[001]-[008] Partition Account Codes
Use these sections to program account codes for each partition.
When using formats other than SIA, these account codes identify the alarm system to the central station when com-
municating partition-specific events.
Note: The system will not communicate if the account code is not programmed. When this condition occurs, Account Code
Not Programmed is briefly displayed on the keypad when exiting Installer Programming mode.
Note: If no phone numbers are programmed, the error message does not occur.
[311]-[318] Partition Call Directions
Use this programming option to select the central station receivers that partition events are communicated to. Call directions
can be programmed for each partition. Each event can be sent to one of four receivers.
[001] Alarm/ Restore
These options control which receiver paths are enabled for Partition 1-8 Alarm and Restore event reporting codes.
To assign an event to a receiver, select one of the following options:
[01] Receiver 1
[02] Receiver 2
[03] Receiver 3
[04] Receiver 4
[002] Tampers (Including System Tampers)/ Restore
These options control which receiver paths are enabled for Partition 1-8 Tamper and Restore event reporting codes.
To assign an event to a receiver, select one of the following options:
[01] Receiver 1
[02] Receiver 2
[03] Receiver 3
[04] Receiver 4
[003] Openings/ Closing
These options control which receiver paths are enabled for Partition 1-8 Opening and Closing event reporting codes. To
assign an event to a receiver, select one of the following options:
[01] Receiver 1
[02] Receiver 2
[03] Receiver 3
[04] Receiver 4
- 107 -

Table of Contents

Other manuals for DSC HS2016

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC HS2016 and is the answer not in the manual?

DSC HS2016 Specifications

General IconGeneral
Mounting TypeWall mount
Power Supply16.5VAC
Battery Backup12VDC
Operating Temperature32°F to 120°F (0°C to 49°C)
Dimensions267mm