Section 5: Programming
7/8 Receiver 4 Supervision Failure/Restore
[361] Wireless Device Events
1/2 Wireless Device AC Failure/Restore
These options are used to enable wireless device AC failure/restore reporting codes. These reporting codes are sent when
a wireless device experiences an AC failure/restore.
3/4 Wireless Device Low Battery Trouble/Restore
These options are used to enable wireless device low battery trouble/restore reporting codes. These codes are sent when a
wireless device experiences a low battery trouble/restore.
5/6 Wireless Device Fault/Restore
These options are used to enable wireless device fault/restore reporting codes. This reporting code is sent when a wireless
device experiences a supervisory fault.
[401] System Test Events
1/2 Walk Test Start/End
Sent when installer walk test is initiated and terminated.
These reporting codes are in addition to the alarm reporting codes for the zones that are tripped during the walk test period,
if configured in section "[382] Communicator Option 3" on page 111.
3 Periodic Test Transmission
Sent when the test transmission programmed in section "[401] System Test Events" on page 106 occurs.
4 Periodic Test Transmission with Trouble
Sent when any of the following trouble conditions are present during a periodic test transmission:
l Fire Zone Trouble
l Battery Trouble
l Fire Zone Alarm (2-Wire Smoke)
l Aux Trouble
l Fire Trouble
l Bell Trouble
l Fire Tamper/Low Sensitivity (WLS)
l Module Supervisory
l Fire Zones Bypassed
l Ground Fault
l Fire Supervisory (Wireless)
l TLM Trouble
l AC Trouble
l FTC Trouble
This reporting code is sent in place of the standard Periodic Test Transmission code.
5 System Test
Sent when a manual system test is performed ([*][6][Master Code][04]).
5.3.13 System Communications
The programming options in this section are used to configure communications between the alarm system and the central
station.
[309] System Call Direction
Use this programming option to select the central station receivers that system events are communicated to. A system event
can be sent to multiple receivers.
[001] Maintenance Events/Restores (all troubles except tampers)
These options control which receiver paths are enabled for maintenance events. To assign a maintenance event to a
receiver, select from the following list:
[01] Receiver 1
[02] Receiver 2
[03] Receiver 3
- 106 -

Table of Contents

Other manuals for DSC HS2016

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC HS2016 and is the answer not in the manual?

DSC HS2016 Specifications

General IconGeneral
Mounting TypeWall mount
Power Supply16.5VAC
Battery Backup12VDC
Operating Temperature32°F to 120°F (0°C to 49°C)
Dimensions267mm