Section 5: Programming
OFF: The alternate communicator and all associated programming functionality are disabled. The auto time update feature is
disabled.
Note: If alternate communicator troubles are present when the communicator is disabled, the troubles are logged, com-
municated, and cleared from [*][2]. When the communicator is re-enabled, the trouble conditions are again logged, com-
municated and indicated in [*][2]. This option must be enabled when attempting to perform a firmware upgrade using the PC-
link header.
6 AC Failure Communication Delay in Hours/Minutes
ON: The AC failure communication delay (section [377]>[002] option 2) is programmed in hours.
OFF: The AC failure communication delay is programmed in minutes.
8 Tamper Limit
ON: When disarmed, the system only communicates module tampers. Zone tampers are not communicated.
OFF: When disarmed, the system communicates all tampers.
[383] Communicator Option 4
1 Phone Number Account Code
ON: The account code communicated to the central station follows the phone number the event is programmed to com-
municate on (programmed in section "[310] Account Codes" on page 107):
l Receiver 1 all events will follow partition 1 account code
l Receiver 2 all events will follow partition 2 account code
l Receiver 3 all events will follow partition 3 account code
l Receiver 4 all events will follow partition 4 account code
OFF: Events follow the account code assigned to each partition when communicating.
Note: This feature only works with CID
2 4 or 6-Digit System Account Code
ON: The programmable account code in section [310][000] is 6 digits long (used for SIA format).
OFF: The programmable account code in section [310][000] is 4 digits long.
5 Communicate FTC Events
ON: The alarm system communicates FTC (failure to communicate) events. The FTC Trouble/Restore reporting code trans-
mission follows the call direction the events are assigned to.
OFF: FTC events are not communicated. FTC Trouble/Restore reporting codes are communicated to the Maintenance call
direction group after the next successful communication.
6 Not used
[384] Communicator Backup Options
2 Receiver 2 Backup Option
ON: Receiver 2 backs up Receiver 1. Receiver 2 is only used if an FTC event is detected on Receiver 1.
Receiver 2 uses the same format programmed for Receiver 1.
OFF: Receiver 2 is independent and will communicate if a number and format are programmed.
3 Receiver 3 Backup Option
ON: Receiver 3 backs up Receiver 2. Receiver 3 is only used if an FTC event is detected on Receiver 2.
Receiver 3 uses the same format programmed for Receiver 2.
OFF: Receiver 3 is independent and will communicate if a number and format are programmed.
4 Receiver 4 Backup Option
ON: Receiver 4 backs up Receiver 3. Receiver 4 is only used if an FTC event is detected on Receiver 3.
Receiver 4 uses the same format programmed for Receiver 3.
OFF: Receiver 4 is independent and will communicate if a number and format are programmed.
[385] Audio Module Talk\Listen Mask
1- Talk/Listen on Receiver 1
ON: 2-way audio sessions can be initiated over receiver 1.