Section 5: Programming
None Always displayed as the 24-hour result when testing wireless keys.
[912] Soak Test
This feature is used to diagnose false alarms. After a false alarm has occurred on a zone, Soak Test mode impedes any aud-
ible alarm conditions or additional false alarm reporting. A record of the false alarm is stored for diagnostic purposes.
[000] Soak Test Duration
This option is used to program the length of time the system remains in soak test. The default is 14 days.
[001]-[128] Zone Soak Test
Soak test can be performed on individual zones. The zone remains in soak test, regardless of the status of the system, until
the soak test timer has expired. If the system is armed when the timer expires, the zones are removed from soak test when
the system is disarmed.
No communications occur for events from a zone in soak test, with the exception of low battery and low battery restore
events and faults generated by low sensitivity in a smoke detector.
A message indicating that the zone is in soak test is displayed when scrolling left or right in the base disarmed keypad
menu.
Note: Soak test is not applied to temperature detector events if it is enabled.
[982] Battery Settings
[000] Panel Battery Settings
01 When disabled, the panel battery is charged at 400mA. When enabled, the battery is charged at 700mA.
[010] High Current Output Battery
Enables and disables the high-current battery charge option for HSM2204 1-4.
[020] 1A Power Supply Battery
Enables and disables the high-current battery charge option for HSM2300 1-4.
5.3.22 Defaults
[989] Default Master Code
This section is used to default the master code to the factory default. After entering this section, key in the installer code then
989.
[989][installer code][989] or [*].
Note: Feature is only available for
EN
models of NEO.
[990] Installer Lockout Enable/Disable
When this option is enabled, an installer can not perform a hardware default; attempts to do so are logged to the event buf-
fer.
An audible indication of installer lockout is provided when powering up the alarm system (the phone line relay clicks rap-
idly). Software default changes can still be made while installer lockout is enabled.
[990][installer code][990] or [*].
[991] Default Keypads
This programming option is used to return system keypads to factory default settings.
[901]- [916] Default Keypads 1-16
This section resets individual keypads to factory defaults. After entering this section, select the keypad to default, key in the
installer code then 991 (or press [*]).
[999] Default All Keypads
This section resets all system keypads to factory defaults. After entering this section, key in the installer code then (*) or 991.
[993] Default Alternate Communicator
This section resets the alternate communicator to factory defaults. Enter [993][installer code][993 or *].
- 121 -

Table of Contents

Other manuals for DSC HS2016

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC HS2016 and is the answer not in the manual?

DSC HS2016 Specifications

General IconGeneral
Mounting TypeWall mount
Power Supply16.5VAC
Battery Backup12VDC
Operating Temperature32°F to 120°F (0°C to 49°C)
Dimensions267mm

Related product manuals