Section 6: Programming Worksheets
013 – Delay Between Force Attempts: (Default: 020 seconds):
014 – Post Dial Wait for Handshake: (Range: 001-255; Default: 040 Seconds; UL=45):
015 – IP/GS Wait for Ack: (Range: 001-255; Default: 060 seconds):
016 – IP/Cellular Fault Check Timer: (Range: 003-255; Default: 010):
[380]
Communicator Option 1
1 – R Communications Enabled
2 – o Restore on Bell Time-out
Description on page 1
3 – o Pulse Dialing
4 – o Pulse Dial after 5th Attempt
5 – o Parallel Communications
6 –
o
Alternate Dial
6 –
R
Alternate Dial
7 – o Reduced Dialing Attempts
8 – o Activity Delinquency
[381]
Communicator Option 2
1 – o Keypad Ringback
Description on page 1
2 – o Bell Ringback
4 – o Closing Confirmation
8 – o Communications Priority Options
[382]
Communicator Option 3
2 – o Walk Test Communication
Description on page 1
4 – o Call Waiting Cancel
5 – o Alternate Communicator Enable/Disable
6 – o AC Failure Communication Delay in Hours
8 – o Tamper Limit
[383]
Communicator Option 4
1 – o Phone Number Account Code
Description on page 1
2 – o 6-Digit Account Code
5 – o Communicate FTC Events
[384]
Communicator Backup Options
2 – R Backup Options - Receiver 2
Description on page 1
3 – o Backup Options - Receiver 3
4 – o Backup Options - Receiver 4
[385]
Audio Module Talk/Listen Mask
Description on page 1
1 –oTalk/Listen on Receiver 1
2 –oTalk/Listen on Receiver 2
3 –oTalk/Listen on Receiver 3
4 –oTalk/Listen on Receiver 4
- 162 -