Appendix 4: Regulatory Approvals
SIA Feature Pro-
gramming Section
Comments Range/Default Requirement
Exit Time
[005]>[001], option 3
Access to Entry and Exit delays and Bell Time Out for the system.
Range:45-
255 seconds
Default: 60
sec.
Required
(programmable)
Exit Delay Restart
[018], option 7
Opening a Delay zone door after it has already been opened and closed during
an exit delay restarts the exit delay timer.
Default:
Enabled
Required
Auto Stay Arm on Un-
vacated Premises
[001]>[001]-[128] Zone
type 05, 06,09
Function key: Forces the system to arm in Stay mode if the occupant does not exit
the premises after pressing the Away function key.
If no exit after
full arm
Default:
Enabled
Required
Exit Time and Progress
Annunciation/Disable or
Remote Arming
[861]>[001]-[005], option
4
System times and audible exit beeps can be disabled when using the wireless key
to stay arm the system. When away arming, audible exit beeps can not be
disabled.
Default:
Enabled
Allowed
Entry delay(s)
[005]>[001]-[008], options
1 and 2
Access to entry and exit delays and bell time out for the system
Note: Combined entry delay and communications delay (abort window) shall not
exceed 60s.
Range: 30 sec.
to 4 min.
Default: 30
sec.
Required
(programmable)
Abort Window for Non-
Fire zones
[002]>[001]-[128], option
7 ON
Access to zone attributes, i.e., swinger shutdown, transmission delay and cross
zone. May be disabled by zone or zone type.
Default:
Enabled
Required
Abort Window Time - for
Non-Fire zones
[377]>[002], option 1
Access to the programmable delay before communicating alarms
Note: Combined entry delay and communications delay (abort window) shall not
exceed 60 seconds.
Range: 00 - 45
sec.
Default: 30
sees
Required
(programmable)
Abort Annunciation An audible tone is generated when an alarm is aborted during the abort window.
Hard-coded
ON
Required
Duress Feature
[*][5]> master code> user
2-95> 5> 2
When this feature is enabled, selected user codes send a duress reporting code
to the central station when used to perform any function on the system. Section
[019], option [6] must be enabled.
Default: N Required
Cancel Window
[377]>[002], option 6
Access to the communications cancel window. Minimum duration must be 5
minutes.
Range: 005-
255
Default: 005
Cancel Annunciation
[308]>[001], option 8
Access to the reporting code for Alarm Canceled.
A Cancel was
transmitted
Default:
Enabled
Required
Cross Zoning
[042]>Selection 3, option
002
Enables cross zoning for entire system. Zones can be enabled for cross zoning
via zone attribute option 8 in sections [002][101] - [128].
Programming
required
Default:
Disabled
Required
Burglary Verification
Timer
[005]>[000], option 3
Access to the programmable Cross Zone timer.
Range: 000-
255 sec.
Default: 60
seconds
Allowed
- 208 -

Table of Contents

Other manuals for DSC HS2016

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC HS2016 and is the answer not in the manual?

DSC HS2016 Specifications

General IconGeneral
Mounting TypeWall mount
Power Supply16.5VAC
Battery Backup12VDC
Operating Temperature32°F to 120°F (0°C to 49°C)
Dimensions267mm