Appendix 4: Regulatory Approvals
Swinger Shutdown for
Alarms
[377]>[001], option 1
Access to the swinger shutdown limit for zone alarms
For all non-fire zones, shut down at 1 to 6 trips.
Default: 2 trips
Required
(programmable)
Swinger Shutdown
Enable
[002]>[001] - [128], option
6 ON
Access to swinger shutdown, transmission delay and cross zone attributes. Zone
attribute option 6 (Swinger Shutdown enabled) is ON.
Non-police
response
zones
Default:
Enabled
Allowed
24-Hr. Auto-verified Fire
[001]>[001]-[128], Zone
type 025 ON
Access to 24-Hr. Auto-verified Fire
Activates if Not restored within the specified time.
Must choose
zone type for
application
Required
Call Waiting Cancel
[382], option 4 OFF
Access to the dialing sequence used to disable call waiting. Call waiting string can
be programmed in [304]
Depends on
user phone
line
Default:
Disabled
Required
System Test:
[*][6] Master Code, option
04
The system activates all keypad sounders, bells or sirens for 2 seconds and all
keypad lights turn on. Refer to user manual (part no. 29008365).
Walk Test Mode:
[*][8][Installer code][901]
This mode is used to test each zone on the system for proper functionality.
Walk Test
Communications
[382], option 2
Enables communication of zone alarms while walk test is active.
Default:
Disabled
Walk Test Start/ End
Reporting Codes
[308][401], options 1 and 2
Access to the reporting codes for walk test start and end times.
EU Compliance Statement
This Product (HS218/HS2064/HS2032/HS2016) is in Conformity with EMC Directive 2004/108/EC based on results using harmonized
standards in accordance with article 10(5), R&TTE Directive 1999/5/EC based on Following Annex III of the directive and LVD directive
2006/95/EC based on results using Harmonized standards.
This product meets the requirements of Class II, Grade 2 equipment as per EN50131-1: 2006+A1:2009, EN50131-3:2009, EN50131-6:2008
(Type A), EN50136-1-1:1997, EN50136-2-1, EN50136-2-3 (ATS2) Standards.
This device is suitable for use in systems with the following notification options.
A (use of two warning devices and internal dialer required
B (self-powered warning device and internal dialer required
C (use of DSC compatible alternate communicator in back-up or redundant mode)
D (use of DSC compatible alternate communicator with encryption enabled required.)
For EN50131 compliant installations only the intrusion portion of the alarm system has been investigated. Fire Alarm and Auxiliary (Medical) Alarm
functions were not included in the evaluation of this product under the requirements of the above mentioned standards.
Additional features implemented for EN 50131 Grade 2:
Fire alarm and CO alarm annunciation
Auxiliary (medical) alarm annunciation
Optional feature implemented for EN 50131 Grade 2:
Removal from mounting tamper detection for non wire-free components
The model HS2128, HS2064, HS2032, HS2016 Control Panel has been certified by Telefication according to EN50131-1:2006 +A1:2009,
EN50131-3:2009, EN50131-6:2008 (Type A) and EN50136-1:1997 (ATS2) for Grade 2, Class II.
- 209 -