Section 4: System Operation
4.7.5 [*][4] Door Chime Enable/Disable
When this feature is enabled, the keypad emits a tone whenever a zone programmed as a Chime type is opened or closed.
Pressing [*][4] toggles between enabled and disabled. The door chime attribute for each zone is programmed in section
[861]-[876], subsections [101]-[228].
A function key can also be programmed to enable/disable this feature. See "Keypad Function Keys" on page 37 for details.
This feature may require an access code. See "[023] System Option 11" on page 95, option 7 for details.
The following door chime sounds may be selected:
l 6 beeps
l "Bing-Bong"
l "Ding-Dong"
l Alarm tone
l Zone Name -Voice Annunciation (HS2LCDWF keypads only)
4.7.6 [*][5] Program Access Codes
Use this section to perform the following functions:
l press [1] to program user codes 0002-1000, and master code 0001
l press [2] to enroll a proximity tag
l press [3] to add a custom label for each user
l press [4] to assign users to partitions
l press [5] to program user attributes
Assign Access Codes
In order to access alarm system functionality, users must be added to the system. This involves creating a unique access
code and assigning attributes to each user. Access codes are programmed via the [*][5] menu.
Access Code Types
The alarm system provides the following access code types:
Code Add User Delete User Arm Disarm [*][5] [*][6] [*][8]
Installer No No No No No No Yes +
Master All* All Yes Yes Yes Yes No
Maintenance No No Yes Yes No No No
User No No Yes Yes No No** No
Supervisor All but Master All but Master Yes Yes Yes Yes No
Duress No No Yes Yes No No No
One-time use No No Yes 1/day No No No
+ If section [020] option 7 is on, a user must enter [*][6][Master Code][05] to give the installer permission to access pro-
gramming.
* Can only change master code if section [015] option 6 is off.
** Yes if [023] option 8 is on.
The Installer and Master codes are system codes. They can be changed but not deleted. The other codes are user-defined
and can be added or deleted as necessary. By default, access codes have the same partition and attribute programming as
the code used to program them.
Access codes are either 4, 6 or 8 digits in length, depending on the setting of programming section [041]. Duplicate codes
are not valid.
Note: EN50131-1 compliant systems using 1000 access codes shall set the access code to 8 digits (section [041], option
02).
Installer Code
This code provides access to Installer Programming [*][8]. The installer code can access all partitions and perform any
keypad function. This code can be programed by the installer in section [006][001]. The default is 5555 (4-digit), 555555 (6-