Section 5: Programming
201-216 – Zone Follower (Zones 1-128)
This output type is assigned to a group of zones and is normally activated, but deactivates when a zone is tripped. Zones are
assigned to this output in the following groups:
201 – Zones 1-8 209 – Zones 65-72
202 – Zones 9-16 210 – Zones 73-80
203 – Zones 17-24 211 – Zones 81-88
204 – Zones 25-32 212 – Zones 89-96
205 – Zones 33-40 213 – Zones 97-104
206 – Zones 41-48 214 – Zones 105-112
207 – Zones 49-56 215 – Zones 113-120
208 – Zones 57-64 216 – Zones 121-128
If multiple zones are enabled, any active zone in that group triggers the output. The PGM will not activate again until all
zones are restored.
5.3.7 [010] PGM Attributes
The following options are used to program the operating characteristics of the main bell and PGM outputs.
[000] Main Bell Mask
This programming section is used to configure the types of audible alarms that trigger the main bell output on the alarm con-
troller. All options are selected by default.
Fire Alarm
ON: Fire alarm ([F] key, Fire zones) activates the main siren.
OFF: Fire alarm does not activate the main siren.
CO Alarm
ON: CO alarm activates the main siren.
OFF: CO alarm does not activate the main siren.
Burglary Alarm
ON: Burglary alarm (Delay, Instant, Interior, Stay/Away, Night, Interior Delay, Instant Stay/Away, Day, 24-hour Burglary) activates the main siren.
OFF: Burglary alarm does not activate the main siren.
24-Hour Flood Alarm
ON: Main bell activates in the event of a 24-Hour Flood alarm.
OFF: Main bell does not activate in the event of a 24-Hour Flood alarm.
Bell Squawks
ON: Squawks activate the main siren. Bell squawks must be enabled to use the following options:
l Bell Squawk on arm (single)
l Bell Squawk on disarm (double)
l Bell Duration Auto-Arm (single every second)
l Bell Squawk on Exit (single every second)
l Bell Squawk on Entry (single every second)
l Bell Squawk on Trouble (single every 10 seconds)
OFF: Squawks do not activate the main siren.
[001]-[164] PGM 001-164 Attributes
The following PGM attributes can be assigned to a PGM. Each attribute has various toggle options, depending on the PGM
type selected (section [009]).
101 – Fire and Burglary
01 – True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
- 77 -