Section 5: Programming
102 Delay Fire and Burglary
01 True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
103 Sensor Reset [*][7][2]
01 True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
03 Access Code Required / No Code Required
ON: Access code required for activation
OFF: No access code required for activation
109 Courtesy Pulse
01 True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
111 Keypad Buzzer Follow
01 True Output/Inverted
ON: deactivated during normal operation, activated when triggered.
OFF: activated during normal operation, deactivated when triggered.
02 Timed Output
ON: output remains active until the PGM output timer expires.
OFF: output remains active until the buzzer condition ends.
09 Entry Delay
ON: activates on entry delay.
OFF: does not activate on entry.
10 Exit Delay
ON: activates on exit delay.
OFF: does not activate on exit delay.
11 Door Chime
ON: activates when chime is enabled.
OFF: does not activate when chime is enabled.
12 Keypad Buzzer Zone
ON: activates when keypad buzzer goes into alarm.
OFF: does not activate when keypad buzzer goes into alarm.
13 Audible Exit Fault
ON: activates when audible exit fault pre-alert begins.
OFF: does not activate when audible exit fault pre-alert begins.
14 Auto-Arm Pre-Alert
ON: activates when auto-arming pre-alert begins.
OFF: does not activate when auto-arming pre-alert begins.
114 Ready To Arm
01 True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
- 78 -

Table of Contents

Other manuals for DSC HS2016

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC HS2016 and is the answer not in the manual?

DSC HS2016 Specifications

General IconGeneral
Mounting TypeWall mount
Power Supply16.5VAC
Battery Backup12VDC
Operating Temperature32°F to 120°F (0°C to 49°C)
Dimensions267mm

Related product manuals