EasyManuals Logo

DSC HS2016 Reference Manual

DSC HS2016
232 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #84 background imageLoading...
Page #84 background image
Section 5: Programming
OFF: activated during normal operation. Deactivated when triggered.
02 PGM Timer
ON: output remains active until an access code is entered or certain criteria have been met, depending on the PGM
type.
OFF: output remains active until the PGM output timer expires.
09 Battery Low
ON: activates when a low battery trouble occurs.
OFF: does not activate when a low battery trouble occurs.
10 Battery Absent
ON: activates when a battery absent trouble occurs.
OFF: does not activate when a battery absent trouble occurs.
165 Prox Used
01 True Output/Latched Output
ON: deactivated during normal operation. Activated when triggered.
OFF: activated during normal operation. Deactivated when triggered.
166 Partition Prox Used
01 True Output/Latched Output
ON: deactivated during normal operation. Activated when triggered.
OFF: activated during normal operation. Deactivated when triggered.
175 Bell Prog Access
01 True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: activated during normal operation. Deactivated when triggered.
176 Remote Operation
01 True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: activated during normal operation. Deactivated when triggered.
184 Open After Alarm
01 True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: activated during normal operation. Deactivated when triggered.
200 - Zone Follower - Single Zone
01 True Output/Inverted
ON: deactivated during normal operation, activated when triggered.
OFF: activated during normal operation, deactivated when triggered.
02 Timed Output
ON: output remains active until the PGM output timer expires.
OFF: output remains active until the zone is restored.
04 Latching
ON: output remains latched until a valid access code is entered or a valid Prox tag is presented.
OFF: output follows the setting of the Timed Output attribute.
05 Follow Alarm
ON: output is activated on zone alarm and stays active until the bell is turned off. See table for operation with bits 2
and 4.
OFF: output is activated on zone opening and deactivated when zone is closed.
- 84 -

Table of Contents

Other manuals for DSC HS2016

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC HS2016 and is the answer not in the manual?

DSC HS2016 Specifications

General IconGeneral
Mounting TypeWall mount
Power Supply16.5VAC
Battery Backup12VDC
Operating Temperature32°F to 120°F (0°C to 49°C)
Dimensions267mm

Related product manuals