34
closed. In order for the output to activate, the door chime
feature must be enabled.
TLM Only (13)
The output will activate when a telephone line trouble is
present.
TLM and Alarm (14)
The output will activate when a telephone line trouble is
present and an alarm occurs on any of the selected parti-
tions.
Failure To Communicate (15)
The output will activate when a Failure to Communicate
trouble is present. The output will stay activated until a suc-
cessful communication is sent to the central station.
Communications Active (16)
The output will activate while the panel is attempting to
communicate with the central station.
Ground Start (17)
The output will activate for a programmable number of sec-
onds before the panel attempts to communicate with the
central station.
NOTE: This output will follow the ’Ground Start’ PGM
pulse time (see 11.4 ‘Output Pulse Times‘). This output
must not be used on UL listed systems.
Kissoff Output (18)
The output will activate for a programmed number of sec-
onds after a successful communication to the central sta-
tion.
NOTE: This output will follow the ’Kissoff Pulse’ PGM
pulse time (see 11.4 ‘Output Pulse Times‘).
Combus Power (19)
This output will deactivate when a Combus reset is per-
formed by the panel.
Ready Status (20)
The output will activate when all the selected partitions are
ready to be armed. If any of the selected partitions are not
ready, the output will deactivate.
Zone Alarm (21)
This output will annunciate when a selected zone has gone
into alarm. Any zone can be selected. If the zone goes into
alarm, the output will activate. The output will remain
active until the partition is armed again.
Zone Follow (22)
This output will follow a selected zone. Any zone can be
selected. If the zone is opened, the output will activate.
When the zone is secured, the output will deactivate. When
the Follows + Alarms system toggle option is enabled, the
output will remain active until the partition that the zone
belongs to is armed or disarmed (ref #[000200]).
Duress (23)
This output will activate when a Duress code is used to per-
form any function.
NOTE: This output will follow the Duress pulse timer
(see 11.4 ‘Output Pulse Times‘).
Buzzer Follow (24)
This output will activate when any of the following events
occur on the selected partitions:
entry delay faults
auto-arm pre-alert 24Hr quick bypass pre-alert
24HR buzzer zone alarm AML supervisory faults
tampers fire supervisory alarms
Remote Operation (25)
This option can be activated remotely using downloading,
and will remain active until deactivated by the download-
ing computer.
Exit Follow (26)
This option will follow the exit delay for the selected parti-
tion(s).
Entry Follow (27)
This output will follow the entry delay for the selected par-
tition(s).
Zone Tamper (28)
This output will activate when any zone tamper alarm
occurs on the selected partitions. It will remain active until
the partition is disarmed (alarm silenced) or the bell time-
out is reached.
Zone Fault (29)
This output will activate when any zone fault alarm occurs
on the selected partitions. It will remain active until the par-
tition is disarmed (alarm silenced) or the bell time-out is
reached.
Zone Tamper Follow (30)
This output will indicate when a zone goes into a tamper
alarm. Any zone can be selected. If the zone is tampered,
the output will activate; when the zone is restored, the out-
put will deactivate. When the Follows + Alarms system
toggle option is enabled, the output will remain active until
the partition that the zone belongs to is armed (ref
#[000200]).
Zone Fault Follow (31)
This output will indicate when a zone goes into a fault
alarm. Any zone can be selected. If the zone is faulted, the
output will activate; when the zone is restored, the output
will deactivate. When the Follows + Alarms system toggle
option is enabled, the output will remain active until the
partition that the zone belongs to is armed (ref #[000200]).
Armed Stay Mode (32)
This output will activate when a selected partition is armed
in the Stay mode (i.e. when the partition is armed with
Stay/Away zones bypassed).
Armed Away Mode (33)
This output will activate when a selected partition is armed
in the Away mode (i.e. when all Stay/Away zones are
active).
2-wire Smoke Alarm (34)
The output will follow the alarm status on the PC4701 2-
wire smoke input, if installed. If the input is in alarm, the
output will activate; when the alarm is restored, the output
will deactivate.
2-wire Smoke Trouble (35)
The output will follow the trouble status on the PC4701 2-
wire smoke input, if installed. If the input exhibits a trouble,
the output will activate; when the trouble is restored, the
output will deactivate.
Waterflow Alarm (36)
The output will follow the alarm status on the PC4701
Waterflow input, if installed. If the input is in alarm, the
output will activate; when the alarm is restored, the output
will deactivate.
Waterflow Trouble (37)
The output will follow the trouble status on the PC4701
Waterflow input, if installed. If the input exhibits a trouble,
the output will activate; when the trouble is restored, the
output will deactivate.
Command Outputs 1-8 (38-45)
The output will activate when the corresponding [*] [7] [1-
8] command is entered on the selected partition. Enter a
pulse time for each output (default = 000 seconds; 005 sec-
onds for Command Output #2). A pulse time of [000] will

Table of Contents

Other manuals for DSC MAXSYS PC4020

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC MAXSYS PC4020 and is the answer not in the manual?

DSC MAXSYS PC4020 Specifications

General IconGeneral
Partitions8
Event Buffer1000 events
Keypads16
Power Supply16.5V, 40VA transformer
Battery Backup12V 7Ah (typical)