48
Appendix A: Reporting Codes
Notes on Contact ID
The following is a list of Contact ID reporting codes. The
first digit (in parentheses) will automatically be sent by
the control. The last two digits are programmed to indi-
cate specific information about the signal.
For example, if zone 1 is an entry/exit point, the alarm
reporting code could be programmed as [34]. The central
station would receive the following:
*BURG - ENTRY/EXIT - 1
In the above example, the ’1’ indicates the zone in alarm.
Notes on SIA Format
If the SIA 1 Account # option is selected, the panel will
send the system account code along with its data trans-
mission (ref # [000401], scroll to option). At the receiver,
the transmission would look similar to this example:
N Ri01 / BA 001
N= New Event
Ri01 = Partition /Area Identifier
BA = Burglary Alarm
001 = Zone 1
4-Digit Reporting Codes
When using 4-digit reporting codes a leading zero will be
added to all reporting codes except for the user numbers
(0000 to 1500).
* A/R = alarms/restorals; O/C = openings/closings; O = other
** PPP = partition number; UUU = user number (user 1000 to 1500 = 999); ZZZ = zone number
Ref. # Reporting Code Code Sent When...
Dialer
Direction*
Contact
ID
SIA Auto Rep
Codes**
[00040300] Zone Alarms zone goes into alarm A/R
see Appendix B ’Zone
Reporting Codes’
[00040301] Zone Restorals alarm condition has been restored A/R
[00040302] Zone Trouble/Tamper zone exhibits a trouble/tamper condition A/R
[00040303] Zone Trouble/Tamper Rest. trouble/tamper condition has cleared A/R
[00040304] Zone Fault zone exhibits a zone fault A/R
[00040305] Zone Fault Rest. zone fault condition has cleared A/R
[00040306] [F] Key Alarm/Rest. Keypad fire alarm (alarm and restore rep.
codes sent together)
A/R (1) 15 FA-000/FH-000
[00040306] [A] Key Alarm/Rest. Keypad auxiliary alarm (alarm and restore rep.
codes sent together)
A/R (1) AA MA-000/MH-
000
[00040306] [P] Key Alarm/Rest. Keypad panic alarm (alarm and restore rep.
codes sent together)
A/R (1) 2A PA-000/PH-000
[00040307] Duress Alarm Duress code entered A/R (1) 21 HA-000
[00040307] Opening After Alarm partition disarmed with alarm in memory A/R (4/5) 58 OR-000
[00040307] Recent Closing alarm occurs within two minutes of partition
arming
A/R (4) 59 CR-000
[00040307] Cross Zone (Police Code)
Alarm
two zones on the same partition go into
alarm within the Police Code Time during any
given armed period (incl. 24Hr zones)
A/R (1) 39 BV-000
[00040307] Door Forced Alarm/Rest. (access control) door forced open alarm event
occurs (PC4820 only)
A/R (1) NONE DF-ZZZ/DR-ZZZ
[00040307] Door Open Too Long Alarm/
Rest.
(access control) door open too long events
occur (PC4820 only)
A/R (1) NONE DN-ZZZ/DH-ZZZ
[00040307] Alarm Cancel a user presses the Cancel function key after
the partition has gone into alarm
A/R (4) A6 BC-UUU
[00040308] General System Tamper/Rest. enrolled module with tamper inputs has a
tamper alarm
O (1) 45 TA-000/TR-000
[00040309] Keypad Lockout max. number of incorrect access codes has
been entered at a keypad
O (4) 21 JA-000
[00040309] 2-wire Alarm/Rest. 2-wire smoke alarm (PC4701 only) A/R (1) 11 FA-999/FH-999
[00040309] Waterflow Alarm/Rest. waterflow zone alarm (PC4701 only) A/R (1) 13 SA-998/SH-998
[00040309] 2-wire Trouble/Rest. 2-wire smoke zone has a trouble (open) condi-
tion (PC4701 only)
A/R (3) 73 FT-999/FJ-999

Table of Contents

Other manuals for DSC MAXSYS PC4020

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC MAXSYS PC4020 and is the answer not in the manual?

DSC MAXSYS PC4020 Specifications

General IconGeneral
Partitions8
Event Buffer1000 events
Keypads16
Power Supply16.5V, 40VA transformer
Battery Backup12V 7Ah (typical)