38
disabled, the panel will send the restoral immediately
when the zone is restored (default=No).
NOTE: DO NOT enable this feature if the previous
’Restore on Bell Time Out’ option is enabled.
NOTE: If Bell Shutdown is to be used, DO NOT enable
this option.
Shut Down 24HRS: If enabled, the swinger shutdown
counters will be reset every day at midnight, or when
the partition is armed. These counters keep track of
how many alarms have occurred on each zone, shut-
ting them down if they reach their limit. If disabled,
the swinger shutdown counters will only be reset
when the partition is armed (default=No).
NOTE: This option should be enabled when using glo-
bal zones.
PC ID: If enabled, the panel will identify all manually
bypassed zones when the partition is armed. The partial
closing reporting code must be programmed for this
feature to work.
If disabled, the panel will only send a partial closing
reporting code to tell the central station that zones were
bypassed when the partition was armed (default=No).
PC on Auto Arm: If enabled, the panel will send the
partial closing reporting code to the central station
when a zone is force armed during auto-arming. If dis-
abled, no partial closing reporting code will be sent
(default=Yes).
PC ID Restores: If enabled, the zone restoral reporting
codes will be transmitted instead of the zone alarm
reporting codes to identify the manually bypassed and
force armed zones upon auto-arming. If disabled, the
zone alarm reporting codes will be sent (default=No).
TLM Enabled: If enabled, the system will test for tele-
phone line faults. The keypads will indicate any faults
detected (default=Yes).
TLM Aud Bell: If enabled, all bells will be audible
when a telephone line trouble is present and the parti-
tion is armed (default=Yes).
FTC Aud Bell: If enabled, a Failure To Communicate
trouble will cause the bell outputs to activate. If dis-
abled, only the keypads will annunciate the trouble
(default=No).
TLM + Alarm Aud: This option will determine
whether the burg bell outputs will activate when a
Transmission Line Monitoring trouble and an alarm
occur simultaneously. If enabled, the bells for the
armed partition will sound.
Ringback: If enabled, the partition keypad will beep
10 times when a successful communication of a closing
to the central station occurs (default=No).
NOTE: If communications are being sent to more than
one telephone number, communications to all numbers
will produce a ringback.
Ringback Sqwk: If enabled, the partition keypad and
the partition bell outputs (Fire/Burg, Inv Fire/Burg,
Burg and Invert Burg) will squawk when a successful
communication of a closing to the central station
occurs (default=No).
NOTE: The Ringback option must be enabled in order
for this feature to function.
Periodic Test: If enabled, the panel will send a test
transmission to the central station (default=No).
If this feature is enabled and a PC4701 module is
enrolled on the system, the panel will alternate send-
ing the periodic test transmission between Line 1 and
Line 2 of the PC4701 so that both communication paths
are tested.
Europe Dial: If enabled, the contact closure to the tele-
phone line is made in a 67/33 make/break ratio. This
is the European standard method of dialing
(default=No).
NOTE: Do not enable this option for North American
installations.
Default Dial: With this option enabled, if panel’s first
attempt to call the central station fails, it will dial on
every subsequent attempt regardless of the presence of
a dial tone. When disabled, if a ‘D’ for dial tone search
precedes the telephone number, the panel will not dial
if dial tone is not present. See 12.1 ‘Telephone Num-
bers‘ for programming the telephone numbers with
dial tone search (default=Yes).
Ph 1-2 Backup: If enabled, the panel will attempt to
report to the second telephone number if it is unable to
communicate using the first telephone number. The
panel will attempt to call for the number of times pro-
grammed as the Maximum Number of Dialing
Attempts. When used as a backup number, the dialer
direction options for the second telephone number
should be disabled (default=No).
Ph 1-3 Backup: This option is similar to ’Ph 1-2 Backup’
except that the panel will backup to the third telephone
number instead of the second (default=No).
NOTE: If the ’Ph 1-2 Backup’ option is also enabled, the
reporting code will be sent to both the second and
third telephone numbers if the panel is unable to com-
municate using the first number.
Ph 2-3 Backup: This option is similar to ’Ph 1-2 Backup’
except that the panel will attempt to report to the third
telephone number if it is unable to communicate using
the second telephone number (default=No).
NOTE: If the ’Ph 1-2 Backup’ option is also enabled, the
reporting code will be sent to the second telephone
number if the panel is unable to communicate using
the first number. If the panel also fails when attempting
to call the second telephone number, the panel will
send the reporting code to the third number.
Busy Tone Det.: If enabled, when a busy tone is
detected for four seconds, the panel will hang-up and
wait for the amount of time programmed as the Busy
Tone Delay before attempting to redial. If disabled, the
panel will not search for busy tone when dialing the
telephone number (default=No).
NOTE: This feature must not be used with the
LINKS1000.
1300 Hz ID: If enabled, the panel emits a 1300Hz iden-
tification tone from the time it dials to the time it hears
the handshake from the receiver. If disabled, no identi-
fication tone is emitted (default=No).
NOTE: This option should not be used with Pager 2,
Pager 3 or Contact ID formats. This feature should not
be used in North America.
Alternate Dial: If enabled, the panel will alternate
between the first and second telephone numbers when
attempting to call the central station, regardless of the

Table of Contents

Other manuals for DSC MAXSYS PC4020

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC MAXSYS PC4020 and is the answer not in the manual?

DSC MAXSYS PC4020 Specifications

General IconGeneral
Partitions8
Event Buffer1000 events
Keypads16
Power Supply16.5V, 40VA transformer
Battery Backup12V 7Ah (typical)

Related product manuals