PowerSeries Neo Installation Guide
l Temporal Three Fire Signal shall be enabled (section [013], option 8 ON)
l Arm/Disarm Bell Squawk shall be enabled when using wireless key
PG4939/PG4929/PG4949 (section [014], option 1 shall be ON)
l A code shall be required for bypassing (section [023], option 4 shall be ON)
l Trouble beeps shall be enabled (section [022], option 7 shall be ON)
l AC trouble indication LED shall be enabled (Keypad Programming, section
[022], options 5 and 6 shall be ON)
l DACT Communicator shall be enabled for Supervising Station Monitoring
(section [380], option 1 shall be ON)
l For UL Residential Fire and burglary installations, a code shall be required to
view the [*][2] trouble menu (Section [023], option 5 shall be ON)
l A test transmission shall be sent to the monitoring station every 7 days (Sec-
tion [377][003] shall be set to 007; 007 is the default setting)
l For UL residential fire applications at least one LCD keypad (model
HS2LCD(P), HS2LCDRF(P)9) or touchscreen (Model HS2TCHP) shall be
used.
l For UL Residential Fire and burglary installations, 2 UL listed compatible
keypads (e.g. HS2LCD(P), HS2LCDRFP9, HS2TCHP) shall be used, each
having communication bus wiring directly connected to the
RED/BLK/YEL/GRN, located on the main control panel board assembly.
l For CO alarm notification, model PG9913 or PG9933 shall be enrolled on
the system (zone type is 24h CO). Both CO detectors provide T4 CO alarm
signal independent of the control unit and meet the 24 hour normal standby
period followed by the 12 hour alarm period requirements. The control panel
provides T4 audible CO alarm for at least 5 minutes following 24 hour nor-
mal standby.
l For UL Residential Fire applications, latching troubles shall be enabled (Sec-
tion [019], Option 2 is ON).
l For UL Residential Fire applications, if a repeater is required, two of the
model PG9920 shall be used for proper signal routing.
l For Fire and CO applications, a RM-1(C) or RM-2 power loop supervision
relay shall be connected to Aux Power Output to report wiring faults if it is
used for powering fire/CO detection devices (for wiring information see
manual 29009812).
Note: For UL Residential Fire applications compliant with UL985 6th edition,
the following guidelines shall be respected when the equipment is used as a
combination alarm system for fire and burglary protection:
l Fire alarm detection devices shall not be powered from the same AUX out-
put (control panel, zone expander, power supply) as burglary alarm initiating
devices.
l Power supply wiring for Fire Alarm Detection devices (Smoke Detectors,
CO Detectors) shall be connected to the control panel AUX output (located
on the main control panel board assembly).
l Power supply wiring for Burglary Alarm Initiating devices (Motion detect-
ors, magnetic contacts, glass break detectors, etc.) shall be connected to the
compatible Power Supply Module AUX outputs (located on the power supply
module board assembly e.g. HSM2300, HSM2204) or expander module AUX
outputs located on the expander module board assembly (e.g. HSM2108,
HSM2208).
Note: The DACT communicator for this product has no line security.
l Telephone Line Monitoring (TLM) shall be enabled (section [015], option 7
shall be ON).
Note: This product is programmed to perform 5 (min.) to 10 (max.) attempts for
communication of an event to the supervising station. If unsuccessful, a Fail To
Communicate (FTC) trouble is generated.
l Test transmission cycle shall be set for monthly transmission (refer to sec-
tion [351]).
Note: For ULC Residential/Commercial installations set for daily test
transmission.
l Wireless Supervision window shall be set to 4 hrs for Fire Installations
(Wireless Programming, section [804]>[802] shall be programmed with the
value 16).
l Wireless Supervision window shall be set to 4 hrs for Burglary Installations
only (Wireless Programming, section [804]>[802] shall be programmed with
the value 96).
l RF Jam detection shall be enabled (refer to Wireless Programming (section
[804][801], option 00 shall be OFF).
l New Alarms will Disconnect 2-way Audio (section [022], option 6 OFF).
ULC Commercial Burglary
The following wireless PowerG devices models are ULC listed under ULC-S304
requirements for use in Commercial Burg applications rated for Security Level
III.
l PG9914
l PG9905
l PG9920
l PG9922
l PG9929
l PG9934P
l PG9935
l PG9938
l PG9944
l PG9945
l PG9949
l PG9974
l PG9984
l PG9984P
l PG9985
l PG9994
l PG9924 l PG9939 l PG9974P
The wireless supervision window shall be set to 4h for such applications and the
tamper detection for removal from mounting location shall be enabled.
UL Central Station and Police Connect with Standard or Encrypted
Line Security Service
l The installation must use the Models TL2803G(R)E IP/3G Interface,
3G2080(R)E 3G Interface or TL280(R)E IP Interface, which communicates
over Cellular Data Network or an Ethernet network 10/100BaseT to the com-
patible Sur-Gard System I/II/III/IV receiver
l Polling time shall be 200 seconds and compromise detection time shall be 6
min.
l For Encrypted line security applications, the Models TL2803G(R)E IP/3G
Interface, 3G2080(R)E 3G Interface or TL280(R)E IP Interface shall have
the Encryption Key enabled (AES128 bit encryption algorithm is validated
under NIST Certificate No.2645
l Wireless Supervision window shall be enabled (refer to Wireless Pro-
gramming, sections [804]>[802])
UL Local, Central Station, Police Connect with No Line Security
Service
l The installation shall use a Bell UL Listed for Mercantile local alarms (e.g.,
Amseco Model MBL10B bell with Model AB-12 bell housing). Connections
from the control unit to the bell shall be made in conduit. (Optional for cent-
ral Station)
l The bell timeout shall be programmed for 15 minutes minimum
l At least one system remote keypad with tamper switch shall be employed
l The integral DACT shall be enabled and shall be programmed to provide a
low battery transmission
l The control panel shall be in a separately listed CMC-1 or PC4050CA attack
resistant enclosure
l The maximum entry delay time shall not exceed 45s as a result of the attack
test. The maximum exit delay time shall not exceed 60 s.
l A tamper switch shall be used to protect the enclosure cover of the control
unit, and shall also be used on the keypad rear to detect removal from the
wall.
l 24 h check in transmission shall be enabled
l Open/Closing acknowledgement enabled (Not Police Station).
l The Installation shall use the internal dialer (DACT) alone or in conjunction
with Models TL2803G(R)E IP/3G Interface, 3G2080(R)E 3G Interface or
TL280(R)E IP Interface, which communicates over Cellular Data Network
or an Ethernet network 10/100BaseT to the compatible Sur-Gard System
I/II/III/IV receiver
UL Home Health Care Signaling Equipment
l There must be at least two keypads, one of either one of the compatible
keypads models HS2LED, HS2LCD(P), HS2ICN(P), HS2LCDRF(P)9,
HS2ICNRF(P)9 and HS2TCHP .
l Each system shall be programmed to activate an audible Trouble signal
within 90 seconds upon loss of microprocessor memory.
l For UL Home Health Care installations, minimum bell time-out is 5 min.
l The HS2TCHP shall be used along with another compatible model keypad in
order to provide audible supervision for homehealth care or medical install-
ations.
ULC Central Station Fire and Burglary Monitoring Installations
l For installation requirements, levels of security, communication modules and
configurations (Refer to the ULC Installation Information Sheet, DSC
#29002157)
l Use a CSA/cUL approved transformer (hardwired connections required for
Fire Monitoring)
l All tamper circuits may be connected to the same zone
Programming
The notes in the programming sections of the PowerSeries Neo Reference
Manual describing the system configurations for UL/ULC listed installations shall
be implemented.
Control of the Protected Premises
In order to have a UL certificated system, the protected area shall be under the
responsibility of one ownership and management (i.e., one business under one
name). This may be a group of buildings attached or unattached with different
addresses but under the responsibility of someone having mutual interest. The
person of mutual interest is not the alarm-installing company.
Note: This does not apply to strip mall applications where each independent
business must have their own separate alarm system.
e.g.,1: A commercial partitioned system that has an office and a warehouse area
in a building where each area can be armed or disarmed independently. e.g.2: A
residential system partitioned so that the garage area is armed separately from
the house.