EasyManua.ls Logo

DSE 720 - Page 12

DSE 720
25 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 12 - 057-001 720 Operating Instructions Issue 3.1 20/12/2005 AM
Parameter Minimum Maximum Default
Timers
0 - Start Delay 0 secs 60 mins 5 secs
1 - Preheat 0 secs 60 secs 0 secs
2 - Cranking Time 3 secs 60 secs 10 secs
3 - Crank Rest Time 3 secs 60 secs 10 secs
4 - Safety On Delay 8 secs 60 secs 8 secs
5 - Warm Up Time 0 secs 10 mins 0 secs
6 - Frequency Alarm Delay (gen transient delay) 0 secs 10 secs 0 secs
7 - Remote Stop Delay Time 0 secs 60 mins 30 secs
8 - Cooling Time 0 secs 30 mins 1 min
9 - ETS Hold Time 0 secs 60 secs 0 secs
10 - Fail To Stop Delay Time 10 secs 60 secs 60 secs
11 - Low DC Voltage Alarm Delay 0 secs 60 mins 5 mins
Generator
12 - Under Frequency 0 60Hz 40Hz
13 - Loading Frequency 20Hz 60Hz 47Hz
14 - Over Frequency 50Hz 72Hz 57Hz
15 - Loading Voltage 50V 333V 212V
16 - Over Current Alarm Limit 50% 120% 110%
17 - Over Current Alarm Type 0 2 1
Possible selections 0 - Warning
1 - Shutdown
2 - Electrical Trip
Engine
18 - Low DC Voltage Alarm Limit 0 25V 8V
19 - Charge Fail Voltage Alarm Limit 0V 25V 8V
Input settings
20 - Low Oil Pressure 5 PSI 150 PSI 15 PSI
21 - High Engine Temperature
90°C 150°C 95
°
C
22 - Remote Start / Simulated Mains input 0 3 0
Possible selections : 0 - Remote start, close to activate
1 - Remote start, open to activate
2 - Simulated mains, close to activate
3 - Simulated mains, open to activate
23 - Aux Input 1 (see note 5) 0 9 8
Possible selections : 0 - Delayed, warning, close to activate
1 - Delayed, warning, open to active
2 - Immediate, warning, close to activate
3 - Immediate, warning, open to activate
4 - Delayed, shutdown, close to activate
5 - Delayed, shutdown. Open to activate
6 - Immediate, shutdown, close to activate
7 - Immediate, shutdown, open to activate
8 - Lamp test, close to activate
9 - Lamp test, open to activate
24 - Aux Input 1 delay 0 secs 10.0 secs 0
25 - Aux Input 2 (see note 6) 0 9 0
Possible selections : 0 - Delayed, warning, close to activate
1 - Delayed, warning, open to active
2 - Immediate, warning, close to activate
3 - Immediate, warning, open to activate
4 - Delayed, shutdown, close to activate
5 - Delayed, shutdown. Open to activate
6 - Immediate, shutdown, close to activate
7 - Immediate, shutdown, open to activate
8 - Electrical trip, close to activate
9 - Electrical trip, open to activate
26 - Aux Input 2 delay 0 sec 10.0 secs 0